SynthesisEuropean radiology2025
Coronary CTA and CT-FFR in trans-catheter aortic valve implantation candidates: a systematic review and meta-analysis.
Synthesis in European radiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Pooled it
- Prognostic value of preoperative CT-derived fractional flow reserve after transcatheter or surgical aortic valve replacement in patients with severe aortic stenosis.BMC medical imaging · 2026Observational
- Value of Coronary CT Angiography in Ruling Out Coronary Artery Disease in Elderly Patients Candidates to TAVI.Journal of personalized medicine · 2026Article
- Computed Tomography Coronary Angiography as a Gatekeeper for Invasive Coronary Assessment Before Transcatheter Aortic Valve Implantation.Medicina (Kaunas, Lithuania) · 2026Review
- Predictors of Diagnostic Inaccuracy of Detecting Coronary Artery Stenosis by Preprocedural CT Angiography in Patients Prior to Transcatheter Aortic Valve Implantation.Diagnostics (Basel, Switzerland) · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesScreening for obstructive coronary artery disease (CAD) with coronary computed tomography angiography (CCTA) could prevent unnecessary invasive coronary angiography (ICA) procedures during work-up for trans-catheter aortic valve implantation (TAVI). CT-derived fractional flow reserve (CT-FFR) improves CCTA accuracy in chest pain patients. However, its reliability in the TAVI population is unknown. This systematic review and meta-analysis assesses CCTA and CT-FFR in TAVI candidates.
methodsPubMed, Embase and Web of Science were searched for studies regarding CCTA and/or CT-FFR in TAVI candidates. Primary endpoint was correct identification and rule-out of obstructive CAD. Results were pooled in a meta-analysis.
resultsThirty-four articles were part of the meta-analysis, reporting results for CCTA and CT-FFR in 7235 and 1269 patients, respectively. Reference standard was mostly anatomical severity of CAD. At patient level, pooled CCTA sensitivity was 94.0% and specificity 72.4%. CT-FFR sensitivity was 93.2% and specificity 70.3% with substantial variation between studies. However, in studies that compared both, CT-FFR performed better than CCTA. Sensitivity of CCTA versus CT-FFR was 74.9% versus 83.9%, and specificity was 65.5% versus 89.8%.
conclusionsNegative CCTA accurately rules out CAD in the TAVI population. CCTA could lead to significant reduction in pre-TAVI ICA, but false positives remain high. Diagnostic accuracy of CT-FFR was comparable to that of CCTA in our meta-analyses, but in studies performing a direct comparison, CT-FFR performed better than CCTA. However, as most studies were small and used CT-FFR software exclusively available for research, a large study on CT-FFR in TAVI work-up using commercially available CT-FFR software would be appropriate before considering routine implementation. KEY POINTS: Question Coronary artery disease (CAD) screening with invasive coronary angiography before trans-catheter aortic valve implantation (TAVI) is often retrospectively unnecessary, revealing no obstructive CAD. Findings Coronary CTA ruled out CAD in approximately half of TAVI candidates. CT-derived fractional flow reserve (CT-FFR) performed similarly overall but better than coronary CTA in direct comparison. Clinical relevance Addition of coronary CTA to TAVI planning-CT to screen for obstructive CAD could reduce negative invasive coronary angiographies in TAVI work-up. CT-FFR could reduce false-positive coronary CTA results, improving its gatekeeper function in this population, but more data is necessary.