ArticleEJNMMI physics2024
Ultra-fast [
Article in EJNMMI physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05023564 (Peking Union Medical College Hospital), which is not on this map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Peking Union Medical College Hospital (PUMCH) Dementia Longitudinal Cohort Study
Who cites it
3 citing papers in PubMed.
- One-Click CT-Based Pipeline for Regional Quantification of Aortic Valve Fibrocalcific Degeneration.Annals of biomedical engineering · 2026Article
- Technical Optimization Strategies for Amyloid PET Under Challenging Acquisition Conditions: A Comprehensive Narrative Review.Diagnostics (Basel, Switzerland) · 2026Review
- Impact of reducedEJNMMI physics · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors.
Funding
Abstract
backgroundThere is a need for faster amyloid PET scans to reduce patients' discomfort, minimize movement artifacts, and increase throughput. The recently introduced uMI Panorama PET/CT system featuring enhanced spatial resolution and sub-200ps TOF offers the potential for shorter scan duration without sacrificing image quality or efficacy to detect Aβ deposition. The study aims to establish a faster acquisition protocol for [
methodsThirty-eight participants (29 Aβ positive and 9 Aβ negative) from a prospective dementia cohort at Peking Union Medical University Hospital underwent routine [
resultsThe subjective image quality evaluation and Aβ detectability results from the two physicians showed both good intra-reader and inter-reader agreements (Cohen's kappa coefficient: 0.759-1.000). The subjective and objective image qualities of the G2min scans were comparable to the G10min scans, whereas adequate image quality was achieved with the G1min and G45s scans (5-point score ≥ 3). Subjective visual diagnosis by two physicians yielded consistent accuracy for G10min, G2min, and G1min groups, but lower specificity for G45s and G30s groups. The objective detection of Aβ status by cortex SUVr across all scan durations maintained perfect discriminatory efficiency and relatively high effect size (Hedge's G: 2.48-2.54).
conclusionsA 1-min ultra-fast scan is feasible for [ CLINICAL
trial registrationNCT05023564. Registered September 2022 https://clinicaltrials.gov/search?term=NCT05023564 .
Indexed as
Identifiers
What Socratic holds