3D CT to 2D X-ray image registration for improved visualization of tibial vessels in endovascular procedures.

Moujan Saderi, Jaykumar H Patel, Calder D Sheagren, Judit Csőre, Trisha L Roy, Graham A Wright

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. The Fusion of Robotics and Imaging: A Vision of the Future.Methodist DeBakey cardiovascular journal · 2025
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Moujan SaderiDepartment of Medical Biophysics, University of Toronto, Toronto, Canada. moujan.saderi@alumni.utoronto.ca.ORCID http://orcid.org/0009-0002-4175-9366
Jaykumar H PatelDepartment of Medical Biophysics, University of Toronto, Toronto, Canada.
Calder D SheagrenDepartment of Medical Biophysics, University of Toronto, Toronto, Canada.
Judit CsőreDeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, USA.
Trisha L RoyDeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, USA.
Graham A WrightDepartment of Medical Biophysics, University of Toronto, Toronto, Canada.

Funding

Canadian Institutes of Health Research - Project Grant PJT156041
6 · The paper itself

Abstract

purposeDuring endovascular revascularization interventions for peripheral arterial disease, the standard modality of X-ray fluoroscopy (XRF) used for image guidance is limited in visualizing distal segments of infrapopliteal vessels. To enhance visualization of arteries, an image registration technique was developed to align pre-acquired computed tomography (CT) angiography images and to create fusion images highlighting arteries of interest.

methodsX-ray image metadata capturing the position of the X-ray gantry initializes a multiscale iterative optimization process, which uses a local-variance masked normalized cross-correlation loss to rigidly align a digitally reconstructed radiograph (DRR) of the CT dataset with the target X-ray, using the edges of the fibula and tibia as the basis for alignment. A precomputed library of DRRs is used to improve run-time, and the six-degree-of-freedom optimization problem of rigid registration is divided into three smaller sub-problems to improve convergence. The method was tested on a dataset of paired cone-beam CT (CBCT) and XRF images of ex vivo limbs, and registration accuracy at the midline of the artery was evaluated.

resultsOn a dataset of CBCTs from 4 different limbs and a total of 17 XRF images, successful registration was achieved in 13 cases, with the remainder suffering from input image quality issues. The method produced average misalignments of less than 1 mm in horizontal projection distance along the artery midline, with an average run-time of 16 s.

conclusionThe sub-mm spatial accuracy of artery overlays is sufficient for the clinical use case of identifying guidewire deviations from the path of the artery, for early detection of guidewire-induced perforations. The semiautomatic workflow and average run-time of the algorithm make it feasible for integration into clinical workflows.

Indexed as

Computed Tomography AngiographyCone-Beam Computed TomographyEndovascular ProceduresImaging, Three-DimensionalPeripheral Arterial DiseaseTibial ArteriesFluoroscopyHumansAutomated registrationEndovascular interventionsImage fusionPeripheral arterial disease