Evidence map›Paper›PMID 39771799›Full record

ArticleSensors (Basel, Switzerland)2024

Characterization of an Inorganic Powder-Based Scintillation Detector Under a UHDR Electron Beam.

Daline Tho, Sam Beddar

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Daline ThoDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.ORCID 0009-0008-8818-6116
Sam BeddarDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA.ORCID 0000-0001-5825-110X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Ultra-high dose rate (UHDR) radiation therapy needs a reliable dosimetry solution and scintillation detectors are promising candidates. In this study, we characterized an inorganic powder-based scintillation detector under a 9 MeV UHDR electron beam. (2) Methods: A mixture of ZnS:Ag powder and optic glue was coupled to an 8 m Eska GH-4001-P polymethyl methacrylate (PMMA) optical fiber. We evaluated the dependence of the detector on dose per pulse (DPP), pulse repetition frequency (PRF), and pulse width (PW). Additionally, we determined the stability and the reproducibility of the detector. (3) Results: The signal ratio between the PMMA clear optical fiber and the ZnS:Ag scintillator was around 210. ZnS:Ag produced a signal yield 54 times greater than that of a BCF-12 plastic scintillator. Signal variation with PRF changes was under 0.5%. The signal was linear to the integrated dose up to the maximum deliverable dose, 180 Gy. The variation in signal was linear to the change in both PW and DPP. Regarding stability, the standard deviation of 10 consecutive irradiations was 0.83%. For the reproducibility, all daily measurements varied within ±1.5%. (4) Conclusions: These findings show that the ZnS:Ag detector can be used for accurate dosimetry with UHDR beams.

Indexed as

detectordosimetryFLASinorganicscintillationscintillator

Identifiers

PMID39771799
PMCPMC11679140

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.