Evidence map›Paper›PMID 39792174›Full record

ArticleLangenbeck's archives of surgery2025

Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients.

Yoo Jin Choi, Su Min Jeon, Sehyeon Yu, Hye-Sung Jo, Dong-Sik Kim, Young-Dong Yu

Abstract read
PubMed Publisher
In one paragraph

Article in Langenbeck's archives of surgery, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yoo Jin ChoiDepartment of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Su Min JeonDepartment of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Sehyeon YuDepartment of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Hye-Sung JoDepartment of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Dong-Sik KimDepartment of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.
Young-Dong YuDepartment of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea. hust1351@naver.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.

methodsThirty non-diabetic pancreatectomy patients participated. We used the FreeStyle Libre Flash Glucose Monitoring System (Abbott Diabetes Care) for continuous interstitial glucose monitoring. Capillary reference glucose levels were checked four times daily. Accuracy was checked using the Clarke Error Grid.

resultsThe mean age of the participants was 56.8 ± 12.0 years, of whom 61.3% underwent pancreaticoduodenectomy and 38.7% underwent distal pancreatectomy. Three patients developed pancreatogenic diabetes after pancreatectomy. The clinical accuracy of continuous glucose monitoring compared with capillary glucose was 43.9% in Zone A (clinically accurate zone) and 99.8% in Zone A + B (low risk of error) of the Clarke Error Grid. No device-related adverse events were reported. Patients rated favorable user acceptability on the questionnaire.

conclusionThis pilot study demonstrated that the CGM device is accurate and safe for patients who underwent pancreatectomy, with favorable user acceptability. Despite these challenges, the study proposes that the CGM device is beneficial for monitoring glucose levels after discharge in patients with impaired glucose levels following pancreatectomy.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringFeasibility StudiesPancreatectomyAdultAgedContinuous Glucose MonitoringFemaleHumansMaleMiddle AgedPilot ProjectsBlood GlucoseCapillary glucoseDiabetes mellitusGlucose monitoringInterstitial glucosePancreatectomy

Identifiers

What Socratic holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.