Evidence map›Paper›PMID 39799476›Full record

ArticleAnalytical chemistry2025

Amplification-Free Attomolar Detection of Short Nucleic Acids with Upconversion Luminescence: Eliminating Nonspecific Binding by Hybridization Complex Transfer.

Jakub Máčala, Saara Kuusinen, Satu Lahtinen, Hans H Gorris, Petr Skládal, Zdeněk Farka, Tero Soukka

Abstract read
In one paragraph

Article in Analytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jakub MáčalaDepartment of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
Saara KuusinenDepartment of Life Technologies/Biotechnology, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland.ORCID 0000-0003-4910-1905
Satu LahtinenDepartment of Life Technologies/Biotechnology, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland.ORCID 0000-0003-2816-7809
Hans H GorrisDepartment of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.ORCID 0000-0003-1148-4293
Petr SkládalDepartment of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.ORCID 0000-0002-3868-5725
Zdeněk FarkaDepartment of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.ORCID 0000-0002-6842-7081
Tero SoukkaDepartment of Life Technologies/Biotechnology, Faculty of Technology, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland.ORCID 0000-0002-1144-6724

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The anti-Stokes emission of photon upconversion nanoparticles (UCNPs) facilitates their use as labels for ultrasensitive detection in biological samples as infrared excitation does not induce autofluorescence at visible wavelengths. The detection of extremely low-abundance analytes, however, remains challenging as it is impossible to completely avoid nonspecific binding of label conjugates. To overcome this limitation, we developed a novel hybridization complex transfer technique using UCNP labels to detect short nucleic acids directly without target amplification. The assay involves capturing the target-label complexes on an initial solid phase, then using releasing oligonucleotides to specifically elute only the target-UCNP complexes and recapturing them on another solid phase. The nonspecifically adsorbed labels remain on the first solid phase, enabling background-free, ultrasensitive detection. When magnetic microparticles were used as the first solid phase in a sample volume of 120 μL, the assay achieved a limit of detection (LOD) of 310 aM, a 27-fold improvement over the reference assay without transfer. Moreover, the additional target-specific steps introduced in the complex transfer procedure improved the sequence specificity of the complex transfer assay compared with the reference assay. The suitability for clinical analysis was confirmed using spiked plasma samples, resulting in an LOD of 190 aM. By increasing the sample volume to 600 μL and using magnetic preconcentration, the LOD was improved to 46 aM. These results highlight the importance of background elimination in achieving ultralow LODs for the analysis of low-abundance biomarkers.

Indexed as

Luminescent MeasurementsNanoparticlesHumansLimit of DetectionLuminescenceNucleic Acid Hybridization

Identifiers

PMID39799476
PMCPMC11780573

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.