Evidence map›Paper›PMID 39823507›Full record

ArticlePloS one2025

Development and laboratory evaluation of a novel IoT-based electric-driven metering system for high precision garlic planter.

Abdallah Elshawadfy Elwakeel, Ahmed Elbeltagi, Ahmed Z Dewidar, Ali Salem, Mohamed Anwer Abdeen

Abstract read
In one paragraph

Article in PloS one, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Abdallah Elshawadfy ElwakeelFaculty of Agriculture and Natural Resources, Department of Agricultural Engineering, Aswan University, Aswan, Egypt.ORCID 0000-0002-9360-051X
Ahmed ElbeltagiFaculty of Agriculture, Agricultural Engineering Department, Mansoura University, Mansoura, Egypt.
Ahmed Z DewidarPrince Sultan Institute for Environmental, Water and Desert Research, Prince Sultan Bin Abdulaziz International Prize for Water Chair, King Saud University, Riyadh, Saudi Arabia.
Ali SalemFaculty of Engineering, Civil Engineering Department, Minia University, Minia, Egypt.ORCID 0000-0001-6176-8345
Mohamed Anwer AbdeenCollege of Engineering, South China Agricultural University, Guangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In order to address many issues, such as the inconsistent and unreliable seeding process in traditional mechanical garlic seed metering systems (SMS), as well as the lack of ability to monitor the effectiveness of the seeding, a highly accurate electric-driven metering system (EDMS) was developed and created specifically for garlic seed planters. This study provided a description of the overall structure and functioning principle, as well as an analysis of the mechanism for smooth transit and delivery. A combination of an infrared (IR) sensor, Arduino Mega board, stepper motor, speed sensor, and a Wi-Fi module was employed to operate the EDMS, as well as monitor and count the quantity of garlic seeds during the planting process and determine the qualified rate (QR) and missing rate (MR). A monitoring system of the planting quality of garlic seeds was created based on the IoT concept. Then, the performance of the EDMS was validated in a laboratory setting utilizing a bench test at six operating velocities of 10, 20, 30, 40, 50, and 60 rpm of the EDMS. The obtained results showed that the correlation coefficient between the actual and detected garlic seed using the garlic seed monitoring and counting system (GSMCS) was 0.9723. Additionally, the EDMS observed a maximum QR of 96.23% at an operating velocity of 20 rpm, with a standard division and standard error of 1.61030 and 0.72015, respectively. Additionally, the EDMS minimized the MR up to 3.77% at the same operating velocity, with standard division and standard error of 1.65325 and 0.73936, respectively. Furthermore, the results indicated a progressive increase in the QR and MQ standard errors as the EDMS's operating velocity increased. Additionally, the sensor's monitoring accuracy gradually declined with an increase in the operating speed of the EDMS. Finally, this study introduced a novel EDMS to garlic seed planters that was not used before. The developed EDMS and GSMCS are technical manuals for developing and designing monitoring systems capable of precisely measuring and identifying the rates of qualifying and missing garlic seed measurements.

Indexed as

GarlicSeedsElectricity

Identifiers

PMID39823507
PMCPMC11741619

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390