Evidence map›Paper›PMID 39844818›Full record

ArticleFrontiers in chemistry2024

Challenges in "probing spectroscopic probes" for noninvasive simultaneous disease diagnosis.

Lopamudra Roy, Shweta Paul, Amrita Banerjee, Ria Ghosh, Susmita Mondal, Monojit Das, Nivedita Pan, Ishitri Das, Soumendra Singh, Debasish Bhattacharya and 2 more

Abstract read
In one paragraph

Article in Frontiers in chemistry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Lopamudra RoyDepartment of Applied Optics and Photonics, University of Calcutta, Kolkata, India.
Shweta PaulDepartment of Paediatric Medicine, Nil Ratan Sircar Medical College and Hospital, Kolkata, India.
Amrita BanerjeeDepartment of Physics, Jadavpur University, Kolkata, India.
Ria GhoshDepartment of Chemical and Biological Sciences, S. N. Bose National Centre for Basic Sciences, Kolkata, India.
Susmita MondalDepartment of Chemical and Biological Sciences, S. N. Bose National Centre for Basic Sciences, Kolkata, India.
Monojit DasDepartment of Zoology, Vidyasagar University, Midnapore, India.
Nivedita PanDepartment of Chemical and Biological Sciences, S. N. Bose National Centre for Basic Sciences, Kolkata, India.
Ishitri DasDepartment of Paediatric Medicine, Nil Ratan Sircar Medical College and Hospital, Kolkata, India.
Soumendra SinghDepartment of Chemical and Biological Sciences, S. N. Bose National Centre for Basic Sciences, Kolkata, India.
Debasish BhattacharyaDepartment of Gynecology and Obstetrics, Nil Ratan Sircar Medical College and Hospital, Kolkata, India.
Asim Kumar MallickDepartment of Paediatric Medicine, Nil Ratan Sircar Medical College and Hospital, Kolkata, India.
Samir Kumar PalDepartment of Chemical and Biological Sciences, S. N. Bose National Centre for Basic Sciences, Kolkata, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Noninvasive diagnosis of human diseases relies on the detection of molecular markers (probes) in a painless manner. Although extrinsic and intrinsic molecular markers are often used, intrinsic disease probes (molecular markers) are preferable because they are naturally present in our body, and deviation in their concentration from normal levels clearly indicates anomalies in human bodies, that is, diseases. In this study, we report noninvasive spectroscopic measurements of total haemoglobin (Hb), bilirubin, and the ratio of oxy- and deoxyhaemoglobin as disease markers for anaemia, jaundice, and oxygen deficiency, respectively, using a meticulously designed optical fibre probe. The challenges in designing the fibre probe for simultaneous noninvasive detection, including optical power, spectral density of the probing light, and resolution of the spectrometer, were found to be critical to accurate measurements. Finally, a fibre-less, highly portable, and low-cost prototype was developed and tested in human clinical trials for the diagnosis of diseases, and these results were compared with conventional techniques (blood tests).

Indexed as

bilirubinhaemoglobinlow costnoninvasiveoxygen saturationportable

Identifiers

PMID39844818
PMCPMC11751013

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.