Evidence map›Paper›PMID 39856483›Full record

ArticleActa neurochirurgica2025

Non-invasive fundoscopy as a tool to estimate intracranial pressure: a large animal model.

Niclas Lynge Eriksen, Frantz Rom Poulsen, Mikkel Schou Andersen, Mathias Just Nortvig

Abstract read
In one paragraph

Article in Acta neurochirurgica, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Improving physiological monitoring and reporting standards in preclinical stroke research.Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2026
    Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Niclas Lynge EriksenDepartment of Neurosurgery, Odense University Hospital, Odense, Denmark. Niclas.Lynge.Eriksen@rsyd.dk.ORCID 0009-0006-8952-4952
Frantz Rom PoulsenDepartment of Neurosurgery, Odense University Hospital, Odense, Denmark.ORCID 0000-0001-5715-6901
Mikkel Schou AndersenDepartment of Neurosurgery, Odense University Hospital, Odense, Denmark.ORCID 0000-0003-4347-6626
Mathias Just NortvigDepartment of Neurosurgery, Odense University Hospital, Odense, Denmark.ORCID 0009-0004-1562-5115

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeIntracranial pressure (ICP) monitoring is in most studies considered essential in avoiding secondary brain injury in patients with intracranial pathologies. Invasive monitoring of ICP is accurate but is unavailable in many clinical and prehospital settings. Non-invasive modalities have historically been difficult to implement clinically. The retinal arteriovenous ratio (A/V ratio) has shown promise through its relationship with ICP. This study aimed to further elucidate the relationship between ICP, A/V ratio and the intraocular pressure (IOP) measured with non-invasive fundoscopy in a porcine model.

methodsWe achieved controlled values of ICP ranging from normal (5-15 mmHg) to elevated (> 20 mmHg) within the same animal subject. Six pigs were included. ICP and IOP was measured using an intraparenchymal pressure monitor and a tonometer, respectively. Fundoscopy was performed at baseline and at predefined ICP values.

resultsMixed-effects linear regression revealed a significant inverse correlation between A/V ratio and ICP ≥ 20 mmHg (slope coefficient - 0.0026734 [95%-CI: -0.0039347 - (-0.0014121)], p < 0.001). For ICP < 20 mmHg there was no change in A/V ratio (p = 0.987). Similar results were seen for ICP > IOP with a mean IOP of 10 mmHg. A Wald test showed no significant difference between ICP > IOP and ICP ≥ 20 mmHg. ROC curve analysis revealed an AUC of 0.64 for ICP ≥ 20 mmHg and 0.71 for ICP > IOP.

conclusionThe results support the hypothesis that an increase in ICP was associated with a decrease in A/V ratio. Although a slightly better fit, the model of ICP > IOP was deemed less clinically relevant than ICP ≥ 20 mmHg because of the subjects' IOP. Further research integrating multifactorial models and machine learning is needed to enhance the diagnostic accuracy of A/V ratio via fundoscopy, enabling it to serve as a cost-effective screening tool.

Indexed as

Intracranial HypertensionIntracranial PressureIntraocular PressureAnimalsDisease Models, AnimalSwineArteriovenous ratioFundoscopyIntracranial pressureNon-invasive

Identifiers

PMID39856483
PMCPMC11762002

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.