Evidence map›Paper›PMID 39860737›Full record

ArticleSensors (Basel, Switzerland)2025

The Design and Validation of an Open-Palm Data Glove for Precision Finger and Wrist Tracking.

Olivia Hosie, Mats Isaksson, John McCormick, Oren Tirosh, Chrys Hensman

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Olivia HosieSchool of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.ORCID 0009-0009-3717-5182
Mats IsakssonSchool of Engineering, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.ORCID 0000-0003-3047-6811
John McCormickCentre for Transformative Media Technologies, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
Oren TiroshSchool of Health and Biomedical Sciences, Royal Melbourne Institute of Technology, Melbourne, VIC 3000, Australia.ORCID 0000-0002-2281-6399
Chrys HensmanDivision of Robotics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design. The new design improves usability and overall functionality by addressing the limitations of traditional closed-palm designs. It is especially beneficial in capturing movements in fields such as physical therapy and robotic surgery. The new glove incorporates resistive flex sensors (RFSs) at each finger and an inertial measurement unit (IMU) at the wrist joint to measure wrist flexion, extension, ulnar and radial deviation, and rotation. Initially the sensors were tested individually for drift, synchronisation delays, and linearity. The results show a drift of 6.60°/h in the IMU and no drift in the RFSs. There was a 0.06 s delay in the data captured by the IMU compared to the RFSs. The glove's performance was tested with a collaborate robot testing setup. In static conditions, it was found that the IMU had a worst case error across three trials of 7.01° and a mean absolute error (MAE) averaged over three trials of 4.85°, while RFSs had a worst case error of 3.77° and a MAE of 1.25° averaged over all five RFSs used. There was no clear correlation between measurement error and speed. Overall, the new glove design proved to accurately measure joint angles.

Indexed as

FingersHandWristEquipment DesignHumansMovementRoboticsWearable Electronic Devicesdata gloveinertial measurement unit (IMU)open-palm designresistive flex sensor (RFS)wearable technology

Identifiers

PMID39860737
PMCPMC11769055

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.