ArticleTurkish journal of emergency medicine
Comparison of different surfaces in resuscitation quality using a real-time feedback device: A manikin study.
Article in Turkish journal of emergency medicine. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- [Technical quality of cardiopulmonary resuscitation after a training intervention and its association with anthropometric variables].Anales del sistema sanitario de Navarra · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesDelivering chest compressions (CCs) at the targeted depth and rate is a crucial aspect of maintaining the quality of cardiopulmonary resuscitation (CPR). Although administering CCs on a firm surface is recommended, it may not always be feasible. This study aimed to determine whether the underlying surface affects CC depth and rate using a real-time feedback device.
methodsAn observational study was conducted on a manikin (ResusciAnne; Laerdal). 25 volunteer emergency medicine physicians performed 2 min of continuous CCs without feedback on the floor, emergency department stretcher (EDS), and ambulance stretcher (AS). The following day, all participants performed an additional 2 min of CCs while receiving audiovisual real-time feedback (ZOLL M2 series). Compression depths and rates were measured and recorded in a real-time feedback device.
resultsA total of 150 CC intervals were analyzed. The mean values of compression depths and rates on all surfaces are within the targeted range for high-quality CPR, except for the mean depth without feedback on the EDS (mean: 6.37 cm). There were a statistically significant difference, with both AS and EDS were achieved deeper compressions than those on the floor (
conclusionsCC's depth are influenced by the underlying surface. It appears more feasible to minimize surface-related differences while maintaining appropriate targets for depth using real-time feedback devices. The mean compression rate could be kept within the targeted range regardless of the surface.