Evidence map›Paper›PMID 39932995›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2025

A deep learning-enabled smart garment for accurate and versatile monitoring of sleep conditions in daily life.

Chenyu Tang, Wentian Yi, Muzi Xu, Yuxuan Jin, Zibo Zhang, Xuhang Chen, Caizhi Liao, Mengtian Kang, Shuo Gao, Peter Smielewski and 1 more

Abstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Chenyu Tang *Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, United Kingdom.ORCID 0000-0002-6368-5639
Wentian Yi *Electrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, United Kingdom.
Muzi XuElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, United Kingdom.
Yuxuan JinThe Cavendish Laboratory, Department of Physics, University of Cambridge, Cambridge CB3 0FZ, United Kingdom.
Zibo ZhangElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, United Kingdom.
Xuhang ChenDepartment of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom.
Caizhi LiaoElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, United Kingdom.
Mengtian KangDepartment of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing 100005, China.
Shuo GaoSchool of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
Peter SmielewskiDepartment of Clinical Neurosciences, University of Cambridge, Cambridge CB2 0QQ, United Kingdom.
Luigi G OcchipintiElectrical Engineering Division, Department of Engineering, University of Cambridge, Cambridge CB3 0FA, United Kingdom.ORCID 0000-0002-9067-2534

Funding

Graphene Flagship 881603UKRI | Engineering and Physical Sciences Research Council (EPSRC) EP/K03099X/1UKRI | Engineering and Physical Sciences Research Council (EPSRC) EP/L016087/1UKRI | Engineering and Physical Sciences Research Council (EPSRC) EP/W024284/1
6 · The paper itself

Abstract

In wearable smart systems, continuous monitoring and accurate classification of different sleep-related conditions are critical for enhancing sleep quality and preventing sleep-related chronic conditions. However, the requirements for device-skin coupling quality in electrophysiological sleep monitoring systems hinder the comfort and reliability of night wearing. Here, we report a washable, skin-compatible smart garment sleep monitoring system that captures local skin strain signals under weak device-skin coupling conditions without positioning or skin preparation requirements. A printed textile-based strain sensor array responds to strain from 0.1 to 10% with a gauge factor as high as 100 and shows independence to extrinsic motion artifacts via strain-isolating printed pattern design. Through reversible starching treatment, ink penetration depth during direct printing on garments is controlled to achieve batch-to-batch performance variation <10%. Coupled with deep learning, explainable AI, and transfer learning data processing, the smart garment is capable of classifying six sleep states with an accuracy of 98.6%, maintaining excellent explainability (classification with low bias) and generalization (95% accuracy on new users with few-shot learning less than 15 samples per class) in practical applications, paving the way for next-generation daily sleep healthcare management.

Indexed as

ClothingDeep LearningSleepWearable Electronic DevicesAdultFemaleHumansMaleMonitoring, PhysiologicTextilesdeep learninge-textile sensorsleep health monitoringsmart garmenttransfer learning

Identifiers

PMID39932995
PMCPMC11848432

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.