ArticleMaterials (Basel, Switzerland)2025
Microscopic and Biomechanical Analysis of PEEK Interspinous Spacers for Spinal Fusion Applications.
Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Spinal fusion is a surgical intervention used to join two or more vertebrae in the spine. An often-used method involves the placement of intervertebral spacers. They are commonly composed of biocompatible materials like polyetheretherketone. It has strength, longevity, and the capacity to interact harmoniously with the human body. Standardized mechanical tests were performed on two distinct implants to assess their biomechanical characteristics. The studies were conducted at a velocity of 2 mm/min. The stopping criteria were determined based on the loads sustained by the 50th percentile. Furthermore, the chemical composition of the implants was assessed using Raman spectroscopy. The implant created via subtractive manufacturing has a significant change in its elastic region at a force of 1300 N, and it begins subsidence when vertebrae are subjected to a load of 1500 N. The integration of microscopic characterization techniques with the mechanical analysis of prostheses in numerous case studies facilitates the biomechanical evaluation of implants.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.