Evidence map›Paper›PMID 39979615›Full record

ArticleEye (London, England)2025

Short-term efficacy and safety of A-stream glaucoma shunt: a 6-month study.

Hae Min Park, Eun Jung Lee, Jong Chul Han, Seungsoo Rho, Jong Hoon Shin, Do Young Park

Abstract read
In one paragraph

Article in Eye (London, England), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hae Min Park *Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Eun Jung Lee *Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Jong Chul HanDepartment of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Seungsoo RhoDepartment of Ophthalmology, CHA Bundang Medical Center, CHA University, Seongnam-si, Republic of Korea.
Jong Hoon ShinPNU Ophthalmology Clinic, Busan, Republic of Korea.
Do Young ParkDepartment of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea. doyoung83.park@gmail.com.ORCID http://orcid.org/0000-0001-6089-6898

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluated the short-term efficacy and safety of the A-stream Glaucoma Shunt (A-stream; MICROT Inc., Republic of Korea) in patients who completed 6 months of follow-up after implantation.

methodsMedical records of 49 patients (49 eyes) who underwent A-stream implantation between October 2023 and February 2024 were retrospectively reviewed. Primary outcomes included surgical success and intraocular pressure (IOP) reduction at 6 months postoperatively. Success was defined as achieving an IOP ≤ 18 mmHg, with at least a 20% reduction from preoperative IOP, and without clinically significant hypotony (IOP < 6 mmHg persisting >1 month or with hypotony maculopathy), classified as qualified (with or without medications) or complete (without medications). Ripcord removal timing and its effect on IOP, postoperative interventions, and complications were analysed.

resultsAt 6 months, the mean IOP significantly decreased from 26.9 ± 8.3 mmHg to 11.9 ± 3.5 mmHg (P < 0.01). Complete success was achieved in 77.6% and qualified success in 93.9% of the eyes. The ripcord was removed in 73.5% of eyes at an average of 1.8 ± 1.3 months postoperatively, which led to further IOP reduction of 6.8 ± 5.0 mmHg 1 month after removal. No cases of clinically significant hypotony or vision-threatening complications were observed.

conclusionsThe A-stream demonstrated excellent short-term efficacy and safety in lowering IOP with high success rates. The ripcord enabled controlled IOP adjustments postoperatively. Further studies are warranted to evaluate long-term outcomes and compare them with conventional surgeries.

Indexed as

GlaucomaGlaucoma Drainage ImplantsIntraocular PressureAdultAgedAged, 80 and overFemaleFollow-Up StudiesHumansMaleMiddle AgedRetrospective StudiesTime FactorsTonometry, OcularTreatment OutcomeVisual Acuity

Identifiers

PMID39979615
PMCPMC12089429

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked