Evidence map›Paper›PMID 40026883›Full record

ArticleBiomedical engineering letters2025

Instant gait classification for hip osteoarthritis patients: a non-wearable sensor approach utilizing Pearson correlation, SMAPE, and GMM.

Wiha Choi, Hieyong Jeong, Sehoon Oh, Tae-Du Jung

Abstract read
In one paragraph

Article in Biomedical engineering letters, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wiha ChoiDepartment of Robotics and Mechatronics Engineering, DGIST, Daegu, 711-785 Republic of Korea.
Hieyong JeongDepartment of Artificial Intelligence Convergence, Chonnam National University, 77 Yongbongro, Bukgu, Gwangju, 61186 Republic of Korea.
Sehoon OhDepartment of Robotics and Mechatronics Engineering, DGIST, Daegu, 711-785 Republic of Korea.
Tae-Du JungSchool of Medicine, Kyungpook National University Hospital, 680 Gukchaebosang-ro, Jung-gu, Daegu, 41404 Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to establish a methodology for classifying gait patterns in patients with hip osteoarthritis without the use of wearable sensors. Although patients with the same pathological condition may exhibit significantly different gait patterns, an accurate and efficient classification system is needed: one that reduces the effort and preparation time for both patients and clinicians, allowing gait analysis and classification without the need for cumbersome sensors like EMG or camera-based systems. The proposed methodology follows three key steps. First, ground reaction forces are measured in three directions-anterior-posterior, medial-lateral, and vertical-using a force plate during gait analysis. These force data are then evaluated through two approaches: trend similarity is assessed using the Pearson correlation coefficient, while scale similarity is measured with the Symmetric Mean Absolute Percentage Error (SMAPE), comparing results with healthy controls. Finally, Gaussian Mixture Models (GMM) are applied to cluster both healthy controls and patients, grouping the patients into distinct categories based on six quantified metrics derived from the correlation and SMAPE. Using the proposed methodology, 16 patients with hip osteoarthritis were successfully categorized into two distinct gait groups (Group 1 and Group 2). The gait patterns of these groups were further analyzed by comparing joint moments and angles in the lower limbs among healthy individuals and the classified patient groups. This study demonstrates that gait pattern classification can be reliably achieved using only force-plate data, offering a practical tool for personalized rehabilitation in hip osteoarthritis patients. By incorporating quantitative variables that capture both gait trends and scale, the methodology efficiently classifies patients with just 2-3 ms of natural walking. This minimizes the burden on patients while delivering a more accurate and realistic assessment. The proposed approach maintains a level of accuracy comparable to more complex methods, while being easier to implement and more accessible in clinical settings.

Indexed as

Gait assessmentGaussian mixture modelHip osteoarthritisPearson correlation coefficientSymmetric mean absolute percentage error

Identifiers

PMID40026883
PMCPMC11871253

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.