Evidence map›Paper›PMID 40028022›Full record

ArticleBio-protocol2025

Voltage clamp fluorometry in

Victoria C Young, Vamseedhar Rayaprolu, Susy C Kohout

Abstract read
In one paragraph

Article in Bio-protocol, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Victoria C YoungDepartment of Biomedical Sciences, Cooper Medical School of Rowan University, Camden, NJ, USA.
Vamseedhar RayaproluPacific Northwest Cryo-EM Center, Oregon Health and Sciences University, Portland, OR, USA.
Susy C KohoutDepartment of Biomedical Sciences, Cooper Medical School of Rowan University, Camden, NJ, USA.

Funding

Molecular mechanisms behind the voltage sensing phosphatase signalingR01GM111685 · NIGMS · MONTANA STATE UNIVERSITY - BOZEMAN · PI KOHOUT, SUSY C · 2015 to 2018
$1.1M
NIGMS NIH HHS R01 GM111685
6 · The paper itself

Abstract

Voltage clamp fluorometry (VCF) is a powerful technique in which the voltage of a cell's membrane is clamped to control voltage-sensitive membrane proteins while simultaneously measuring fluorescent signals from a protein of interest. By combining fluorescence measurements with electrophysiology, VCF provides real-time measurement of a protein's motions, which gives insight into its function. This protocol describes the use of VCF to study a membrane protein, the voltage-sensing phosphatase (VSP). VSP is a 3 and 5 phosphatidylinositol phosphate (PIP) phosphatase coupled to a voltage sensing domain (VSD). The VSD of VSP is homologous to the VSD of ion channels, with four transmembrane helices (S1-S4). The S4 contains the gating charge arginine residues that sense the membrane's electric field. Membrane depolarization moves the S4 into a state that activates the cytosolic phosphatase domain. To monitor the movement of S4, the environmentally sensitive fluorophore tetramethylrhodamine-6-maleimide (TMRM) is attached extracellularly to the S3-S4 loop. Using VCF, the resulting fluorescence signals from the S4 movement measure the kinetics of activation and repolarization, as well as the voltage dependence of the VSD. This protocol details the steps to express VSP in

Indexed as

Tetramethylrhodamine-6-maleimide (TMRM)Two-electrode voltage clamp (TEVC)Voltage clamp fluorometry (VCF)Voltage-sensing phosphatase (VSP)

Identifiers

PMID40028022
PMCPMC11865819

What Socratic holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.