Evidence map›Paper›PMID 40080141›Full record

ArticleEuropean journal of nuclear medicine and molecular imaging2025

CT-free attenuation and Monte-Carlo based scatter correction-guided quantitative

Zahra Mansouri, Yazdan Salimi, Nicola Bianchetto Wolf, Ismini Mainta, Habib Zaidi

Abstract read
In one paragraph

Article in European journal of nuclear medicine and molecular imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Swin UNETR-based prediction of [BMC medical imaging · 2026
    Article
  4. Article
  5. Article
  6. Review
  7. Evaluation of end-to-end 3D absorbed dose distribution inEuropean journal of nuclear medicine and molecular imaging · 2026
    Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zahra MansouriDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, CH-1211, Switzerland.
Yazdan SalimiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, CH-1211, Switzerland.
Nicola Bianchetto WolfDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, CH-1211, Switzerland.
Ismini MaintaDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, CH-1211, Switzerland.
Habib ZaidiDivision of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, Geneva, CH-1211, Switzerland. habib.zaidi@hcuge.ch.ORCID 0000-0001-7559-5297

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis work aimed to develop deep learning (DL) models for CT-free attenuation and Monte Carlo-based scatter correction (AC, SC) in quantitative

methodsData of 190 patients who underwent

resultsThe average ± SD of the voxel-level quantitative metrics for AC task, are mean error (ME (Gy)): -0.026 ± 0.06, structural similarity index (SSIM (%)): 99.5 ± 0.25, and peak signal to noise ratio (PSNR (dB)): 47.28 ± 3.31. These values for SC task are - 0.014 ± 0.05, 99.88 ± 0.099, 55.9 ± 4, respectively. For ASC task, these values are as follows: -0.04 ± 0.06, 99.57 ± 0.33, 47.97 ± 3.6, respectively. The results of voxel level gamma evaluations with three different criteria, namely "DTA: 4.79, DD: 1%", "DTA:10 mm, DD: 5%", and "DTA: 15 mm, DD:10%" were around 98%. The mean absolute error (MAE (Gy)) for tumor and whole normal liver across tasks are as follows: 7.22 ± 5.9 and 1.09 ± 0.86 for AC, 8 ± 9.3 and 0.9 ± 0.8 for SC, and 11.8 ± 12.02 and 1.3 ± 0.98 for ASC, respectively.

conclusionWe developed multiple models for three different clinically scenarios, namely AC, SC, and ASC using the patient-specific Monte Carlo scatter corrected and CT-based attenuation corrected images. These task-specific models could be beneficial to perform the essential corrections where the CT images are either not available or not reliable due to misalignment, after training with a larger dataset.

Indexed as

Deep LearningImage Processing, Computer-AssistedMonte Carlo MethodRadiation DosageScattering, RadiationTomography, Emission-Computed, Single-PhotonYttrium RadioisotopesAgedFemaleHumansMaleMiddle AgedRadiometryRadiotherapy DosageYttrium-90Yttrium Radioisotopes90Y dosimetryAttenuation correctionDeep learningScatter correctionSPECT/ CT

Identifiers

PMID40080141
PMCPMC12222404

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.