Investigating the impact of different time delays between OCT signal and k-clock signal on the structural and vascular imaging in SS-OCT.

Miaohua Chen, Zhaodong Lu, Peijun Tang, Gongpu Lan, Yanping Huang, Jia Qin, Lin An, Haixia Qiu, Jingjiang Xu

Abstract read
In one paragraph

Article in Biomedical optics express, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Miaohua ChenGuangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.
Zhaodong LuGuangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.
Peijun TangCollege of Biophotonics, South China Normal University, Guangzhou 510006, China.
Gongpu LanGuangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.ORCID https://orcid.org/0000-0002-6928-2398
Yanping HuangGuangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.
Jia QinInnovation and Entrepreneurship Teams Project of Guangdong Pearl River Talents Program, Guangdong Weiren Meditech Co., Ltd, Foshan, Guangdong 528051, China.
Lin AnInnovation and Entrepreneurship Teams Project of Guangdong Pearl River Talents Program, Guangdong Weiren Meditech Co., Ltd, Foshan, Guangdong 528051, China.
Haixia QiuDepartment of Laser Medicine, the First Medical Centre, Chinese PLA General Hospital, Beijing 100853, China.
Jingjiang XuGuangdong-Hong Kong-Macao Joint Laboratory for Intelligent Micro-Nano Optoelectronic Technology, School of Physics and Optoelectronic Engineering, Foshan University, Foshan, Guangdong 528000, China.ORCID https://orcid.org/0000-0002-0016-5791

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

High-quality swept-source optical coherence tomography (SS-OCT) imaging systems require precise synchronization between the OCT signal and the k-clock signal. However, in practical applications, an uncertain time delay between these signals can cause inaccurate k-space sampling, leading to degraded imaging resolution. This study first simulates the axial resolution degradation curve caused by varying time delays and experimentally validates the results. Additionally, the effects of different time delays on both OCT structural and blood flow images are systematically investigated through experiments. To address this issue, a numerical calibration method is implemented to compensate for the nonlinear phase component. This approach involves acquiring two reflection signals at different depths, unwrapping the phase, performing high-order polynomial fitting, and removing nonlinear phase components induced by time delay, which effectively corrects the resolution degradation. Experiments conducted on semi-transparent white tape, blood flow phantom, and human nailfold demonstrate that the proposed correction algorithm significantly improves the axial resolution of both structural and blood flow images. The findings indicate that our investigation and the developed calibration method are instrumental in reconstructing high-resolution SS-OCT images, which are essential for accurate diagnosis and effective treatment monitoring in clinical applications.