ArticleThe international journal of cardiovascular imaging2025
Quantification of water and lipid composition of perivascular adipose tissue using coronary CT angiography: a simulation study.
Article in The international journal of cardiovascular imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Early detection of vascular inflammation via perivascular adipose tissue (PVAT) compositional changes (e.g., increased water content) could improve cardiovascular risk stratification. However, CT-based measurements face variability due to tube voltage and patient size. This study aims to quantify perivascular adipose tissue (PVAT) composition (water, lipid, protein) using coronary CT angiography and assess impacts of tube voltage, patient size, and positional variability on measurements. A 320-slice CT simulation generated anthropomorphic thorax phantoms (small, medium, large) with fat rings mimicking different patient sizes. Ten randomized water-lipid-protein inserts were placed within the thorax phantom. Three-material decomposition was applied using medium phantoms with different tube voltages and different patient sizes at 120 kV. PVAT CT number (HU) increased with higher tube voltages and larger patient sizes. The root-mean-squared errors (RMSE) for water volumetric fraction measurements were 0.26%, 0.64%, 0.01%, and 0.15% for 80, 100, 120, and 135 kV, respectively, and 0.19%, 0.35%, and 0.61% for small, medium, and large size phantoms at 120 kV, respectively. The root-mean-squared deviations (RMSD) were 3.52%, 2.94%, 4.96%, and 6.00% for 80, 100, 120, and 135 kV, respectively, and 3.82%, 3.74%, and 6.05% for small, medium, and large size phantoms at 120 kV, respectively. Clinically relevant water fractions spanned 17-37%, with inflammation expected to alter values by approximately 5%. The findings of this study indicate that, after accounting for the effects of tube voltage and patient size, perivascular adipose tissue CT number can be quantitatively represented in terms of its water composition. This decomposition method has the potential to enable quantification of water composition and facilitate early detection of coronary artery inflammation.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.