Evidence map›Paper›PMID 40212135›Full record

ArticleAnnals of medicine and surgery (2012)2025

Comparison of diagnostic accuracy of electrocardiogram-based versus photoplethysmography-based smartwatches for atrial fibrillation detection: A Systematic Review and Meta-Analysis.

Dan Yang Luo, Zhi Wei Zhang, Olivier Sibomana, Salomon Izere

Abstract read
In one paragraph

Article in Annals of medicine and surgery (2012), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Dan Yang LuoDepartment of Internal Medicine, Inner Mongolia Autonomous Region People's Hospital, China.
Zhi Wei ZhangDepartment of Oncology, The Affiliated Hospital of Inner Mongolia Medical University, Hohhot, China.
Olivier SibomanaDepartment of General Medicine and Surgery, College of Medicine and Health Sciences, University of Rwanda, Kigali, Rwanda.
Salomon IzereDepartment of General Medicine and Surgery, College of Medicine and Health Sciences, University of Rwanda, Kigali, Rwanda.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Atrial fibrillation (AF), the most prevalent cardiac arrhythmia, significantly affects morbidity and mortality, making early detection crucial for preventing stroke and heart failure. Recent advancements in wearable technology have introduced smartwatches as potential tools for continuous non-invasive AF detection. Objective: This systematic review and meta-analysis aimed to evaluate and compare the diagnostic accuracy of electrocardiography (ECG)-and photoplethysmography (PPG)-based smartwatches in detecting AF. Methodology: A comprehensive search was conducted on PubMed, Google Scholar, and other databases from 18 August to 23 September 2024, to fetch original studies that evaluated performance metrics of ECG and PPG smartwatches in AF detection. The obtained literature was screened according to preset inclusion and exclusion criteria. For included studies, the random-effects model was used to calculate their pooled sensitivity and specificity in AF detection using Jamovi 2.3.28 software. A significance threshold of Results: Out of the 2564 studies screened, 25 met the inclusion criteria: 11 on PPG and 14 on ECG smartwatches. PPG smartwatches exhibited higher diagnostic performance with a pooled sensitivity of 97.4% (95% CI: 96.5-98.3) and specificity of 96.6% (95% CI: 94.9-98.3). Conversely, ECG smartwatches showed a pooled sensitivity of 83% (95% CI: 78-88) and specificity of 88.4% (95% CI: 84.5-92.2), lower than PPG smartwatches. Conclusion: PPG-based smartwatches outperformed ECG-based devices in AF detection, offering higher sensitivity and specificity. Even though both modalities are effective in AF detection, the considerable variability in ECG smartwatch performance highlights the need for further research and standardization.

Indexed as

atrial fibrillationcardiac arrythmiaECG smartwatchesPPG smartwatcheswearable technology

Identifiers

PMID40212135
PMCPMC11981249

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.