Improving decomposition image quality in dual-energy chest radiography using two-dimensional crisscrossed anti-scatter grid.

Duhee Jeon, Younghwan Lim, Hyesun Yang, Myeongkyu Park, Kyong-Woo Kim, Hyosung Cho

Abstract read
In one paragraph

Article in Medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Duhee JeonDepartment of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea.
Younghwan LimDepartment of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea.
Hyesun YangDepartment of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea.
Myeongkyu ParkR&D Center, JPI Healthcare Co., Ltd., Seoul, Republic of Korea.
Kyong-Woo KimR&D Center, JPI Healthcare Co., Ltd., Seoul, Republic of Korea.
Hyosung ChoDepartment of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea.

Funding

Korea Medical Device Development Fund 2710002041Korea Medical Device Development Fund RS-2023-00239324
6 · The paper itself

Abstract

backgroundChest radiography is a widely used medical imaging modality for diagnosing chest-related diseases. However, anatomical structure overlap hinders accurate lesion detection. While the dual-energy x-ray imaging technique addresses this issue by separating soft-tissue and bone images from an original chest radiograph, scattered radiation remains a significant challenge in decomposition image quality. PURPOSE: This work aims to conduct dual-energy material decomposition (DEMD) in chest radiography using a two-dimensional (2D) crisscrossed anti-scatter grid to improve decomposition image quality by effectively removing scattered radiation.

methodsA 2D graphite-interspaced grid with a strip density of N = 1.724 lines/mm and grid ratio r = 6:1 was fabricated using a high-precision sawing process. The grid characteristics were evaluated using the IEC standard fixture. A 2D-grid-based DEMD process, which involves the acquisition of low- and high-kV radiographs with a 2D grid, generation of a pairwise decomposition function using a calibration wedge phantom, and decomposition of soft-tissue and bone images using the decomposition function, was implemented, followed by software-based grid artifact reduction. Experiments were conducted on a commercially available chest phantom using an x-ray imaging system operating at two tube voltages of 70 and 120 kVp. The decomposition image quality of the proposed DEMD and conventional dual-energy subtraction methods was compared for the cases of no grid, software-based scatter correction, 1D grid (N = 8.475 lines/mm and r = 12:1), and 2D grid.

resultsThe 2D grid demonstrated superior scatter radiation removal ability with scatter radiation transmission of 6.34% and grid selectivity of 9.67, representing a 2.6-fold decrease and a 2.7-fold improvement over the 1D grid, respectively. Compared to other competitive methods, the 2D-grid-based DEMD method considerably improved decomposition image quality, with improved lung structure visibility in selective soft-tissue images.

conclusionsThe proposed DEMD method yielded high-quality dual-energy chest radiographs by effectively removing scattered radiation, demonstrating significant potential for improving lesion detection in clinical practice.

Indexed as

Image Processing, Computer-AssistedRadiography, ThoracicScattering, RadiationArtifactsHumansPhantoms, Imagingchest radiographydual‐energy material decompositiondual‐energy subtractiontwo‐dimensional anti‐scatter grid

Identifiers

PMID40216589
PMCPMC12257438

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.