Trial reportDiabetic medicine : a journal of the British Diabetic Association2025
Impact of Simplera Sync™ sensors and Extended™ Wear Infusion Sets on glycaemia and system performance of the MiniMed™ 780G system in children and young adults with previously high HbA1c.
Trial report in Diabetic medicine : a journal of the British Diabetic Association, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A systematic literature review and meta-analysis of real-world evidence on commercially available automated insulin delivery systems in people with type 1 diabetes.Diabetes, obesity & metabolism · 2026Pooled it
- Impact of Simplera Sync™ sensors and Extended™ Wear Infusion Sets on glycaemia and system performance of the MiniMed™ 780G system in children and young adults with previously high HbA1c.Diabetic medicine : a journal of the British Diabetic Association · 2025Trial
- CGM Accuracy in a Fragmented Regulatory Landscape: A Commentary on Harmonisation and Recent Evidence.Diabetes, obesity & metabolism · 2026Article
- Outcomes of Diabetes Management with Continuous Glucose Monitoring Technology.Archives of internal medicine research · 2026Article
- Metrics in pregnancy: is it the time for new glycaemic goals for pregnant women with type 1 diabetes? An experience with advanced hybrid closed loop.Acta diabetologica · 2026Article
- Enhancing user experience with an automated insulin delivery system by upgrading to a next generation sensor.Diabetes & vascular disease researchArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
aimsThe MiniMed™ 780G improves glycaemia and reduces burden in type 1 diabetes. We investigated how new all-in-one "Simplera Sync™" sensors and 7-day Extended™ Wear Infusion Sets (EIS) affect glycaemia and system performance in young people with previously elevated HbA1c levels (≥69 mmol/mol [≥8%]) after transitioning from 780G with Guardian 4™ sensors and 3-day infusion sets.
methodsWe conducted an extension phase analysis in 75 participants (aged 7-25 years) initially enrolled in the CO-PILOT randomised controlled trial. For this analysis, baseline was defined as the period following the use of 780G with Guardian 4™ sensors and 3-day infusion sets. Participants then transitioned to 780G with Simplera Sync™ and EIS. We compared glycaemic and system performance outcomes from baseline to those after the transition to 780G with Simplera Sync™ and EIS.
resultsBaseline HbA1c was 66.1 mmol/mol ± 14.2 mmol/mol and remained stable at 66.7 mmol/mol ± 11.2 mmol/mol after the transition (p = 0.38). Time in range (3.9-10.0 mmol/L [70-180 mg/dL]) at baseline was 58.5% ± 14.9% and 60.4% ± 15.7% after transition (p = 0.09). Time in tight range (3.9-7.8 mmol/L [70-140 mg/dL]) increased from 38.1% ± 13.1% at baseline to 40.5% ± 13.6% after the transition (p = 0.04). While using 780G with Simplera Sync™ and EIS, automation time increased from baseline 79.2% ± 25.9% to 85.8% ± 21.8% (p = 0.007), and sensor wear time from 80.7% ± 22.4% at baseline to 88.4% ± 17.2% (p < 0001).
conclusionsSimplera Sync™ and EIS improved time in automation and sensor wear time when using 780G AHCL in this high-risk young population. This was associated with incremental improvement in time in tight range despite the challenges of this population.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.