ArticleSensors (Basel, Switzerland)2025
Efficacy of a Waist-Mounted Sensor in Predicting Prospective Falls Among Older People Residing in Community Dwellings: A Prospective Cohort Study.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 synthesis or guideline pooled it.
- Accuracy of wearable devices in predicting falls in older adults: a systematic review and meta-analysis.Frontiers in public health · 2026Pooled it
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
Falls pose a significant health risk for older people, necessitating accurate predictive tools for fall prevention. This study evaluated the sensitivity of a wearable waist-belt sensor, the Booguu Aspire system, in predicting prospective fall incidents among 37 community-dwelling older people in Hong Kong. A prospective cohort design was employed, involving two analytical groups: the overall cohort and a subset with cognitive performance data available, measured using the Montreal Cognitive Assessment (MoCA). Participants were categorized into moderate- or high-risk groups for falls using the sensor and further assessed with physical function tests, including the Single Leg Stand Test (SLST), 6 Meter Walk Test (6MWT), and Five Times Sit to Stand Test (5STS). Fall incidents were monitored for 12 months through quarterly follow-up phone calls. Statistical analyses showed no significant differences in physical performance between high- and moderate-risk groups and no significant correlations between sensor-based fall risk ratings and physical function test outcomes. The SLST, 6MWT, 5STS, and MoCA tests classified sensor-determined fall risk ratings with accuracies of 51.4%, 64.9%, 59.5%, and 50%. The sensor showed low sensitivity, with 13.51% true positives for fallers and a 20% sensitivity for high-risk individuals. ROC analysis yielded an Area Under the Curve of 0.688. Our findings indicate that the wearable waist-belt Sensor System may not be a sensitive tool in predicting prospective fall incidents. The algorithm for fall risk classification in the wearable sensor merits further exploration.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.