ArticleZeitschrift fur medizinische Physik2026

Standardization of bone mineral density and microstructure from high-resolution CT-scans of the spine in a multicenter setting.

Jaime A Peña, Reinhard Barkmann, Stefan Reinhold, Timo Damm, Tobias Fricke, Jan Bastgen, Felix Thomsen, Claus-C Glüer

Abstract readMulticenter Study
In one paragraph

Article in Zeitschrift fur medizinische Physik, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jaime A PeñaSection Biomedical Imaging, Department of Radiology and Neuroradiology University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany. Electronic address: jaime.pena@rad.uni-kiel.de.
Reinhard BarkmannSection Biomedical Imaging, Department of Radiology and Neuroradiology University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.
Stefan ReinholdMultimedia Information Processing Group, Department of Computer Science, Christian-Albrechts University of Kiel (CAU), Kiel, Germany.
Timo DammSection Biomedical Imaging, Department of Radiology and Neuroradiology University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.
Tobias FrickeDepartment of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.
Jan BastgenOrthopedics and Trauma Surgery Clinic, Lubinus Clinicum, Kiel, Germany.
Felix ThomsenNational Scientific and Technical Research Council, Institute of Computer Science and Engineering, National University of the South, Bahía Blanca, Argentina; Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling University Medical Center, Ruhr University Bochum, Minden, Germany.
Claus-C GlüerSection Biomedical Imaging, Department of Radiology and Neuroradiology University Medical Center Schleswig-Holstein (UKSH), Kiel, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeQuantitative Computed Tomography (QCT) has not fully addressed the need to reduce intra- and inter-scanner variability for Osteoporosis and bone-related studies, which can lead to inaccuracies when pooling data from different CT manufacturers, models, devices, or protocols. In this context, the aim of this work was to develop ex vivo methods for the standardization of bone mineral density and microstructural parameters. MATERIALS AND

methodsSix human vertebral body specimens embedded in poly-methyl methacrylate (PMMA) were scanned ex vivo inside an anthropomorphic abdomen phantom in eight different CT-scanners. We measured 3D trabecular and cortical bone mineral density (Tb.BMD and Ct.BMD at the peeled spongiosa and the vertical cortex, respectively), trabecular separation (Tb.Sp) and cortical thickness (Ct.Th). Standardization of Tb.BMD and Ct.BMD across CT-scanners was conducted by correcting for the influence of PMMA and kernel related differences in the segmented cortical volume. For Tb.BMD and Ct.BMD two CT-scanners, where the majority of the patients were scanned, were used as reference. For Tb.Sp standardization we accounted for the image binarization threshold and used high-resolution peripheral QCT (HR-pQCT) as reference. Cross-calibration factors were obtained for each CT-scanner from which the cross-calibrated measures xTb.BMD, xCt.BMD and xTb.Sp were computed both ex vivo and in vivo. Agreement of the ex vivo measurements with respect to the references was quantified with Lin's concordance correlation coefficient (r

resultsAfter cross-calibration the overall ex vivo mean Tb.BMD across CT-scanners was basically maintained, changing only from 119.0 mgHA/cm

conclusionThe improved inter-scanner agreement with corresponding reduced variability underscores the importance of cross-calibration of bone mineral density and microstructural parameters. For the in vivo application of the methods, cross-calibrated Tb.Sp improved fracture prediction in patients, whereas cross-calibrated BMD had no discernible impact, possibly due to the distribution of patients across the participating CT-centers and the already high fracture classification power of Tb.BMD.

Indexed as

Bone DensitySpineTomography, X-Ray ComputedAgedFemaleHumansMalePhantoms, ImagingReproducibility of ResultsSensitivity and SpecificityBone microstructureCross-calibrationMulticenter studiesQCTStandardization