Evidence map›Paper›PMID 40346256›Full record

ArticleScientific reports2025

Noninvasive blood glucose monitoring using a dual band microwave sensor with machine learning.

Mariam Farouk, Anwer S Abd El-Hameed, Angie R Eldamak, Dalia N Elsheakh

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Mariam FaroukElectrical Department, Faculty of Engineering and Technology, Badr University in Cairo, Badr, 11829, Egypt.
Anwer S Abd El-HameedMicrostrip Department, Electronics Research Institute (ERI), El Nozha, Giza, 4473221, Egypt.
Angie R EldamakElectronics and Communications Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, 11517, Egypt.
Dalia N ElsheakhElectrical Department, Faculty of Engineering and Technology, Badr University in Cairo, Badr, 11829, Egypt. daliaelsheakh@eri.sci.eg.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The potential for continuous non-invasive blood glucose monitoring has attracted a lot of interest in the field of medical diagnostics. This paper provides a new shape of a dual-band bandpass filter (DBBPF) acting as a microwave transmission line sensor for continuous non-invasive blood glucose monitoring operating at 2.45 and 5.2 GHz. The proposed system uses the interaction between biological tissues and microwave signals to correctly assess blood glucose levels. The proposed dual-band bandpass filter (DBBPF), comprises three split ring resonator (SRR) cells with different dimensions. It is designed to operate as a sensor with improved sensitivity, compact dimensions, and a high-quality factor. It also ensures a reasonable bandwidth for lower and higher bands of 8.6 and 2%, respectively in the industrial, scientific, medical band, and the wireless local area network (ISM and WLAN) Bands. A dual-band filter enhances measurement sensitivity and specificity by targeting specific frequency ranges where glucose exhibits distinctive dielectric responses, thereby providing redundant data points for accurate glucose level determination. Glucose concentrations can be evaluated by measuring the changes in the dielectric properties of blood by sending microwave waves through the body and assessing the collected S-parameter signals. The measurement parameters encompass the reflection, phase, magnitude, as well as transmission parameters. This yields multiple evaluations of the glucose-induced alterations. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. Machine learning models are employed to analyze the sensor data, improving the accuracy of diabetes detection. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. A Cole-Cole model, implemented using MATLAB, is utilized for the phantom finger model. The main results reveal the success of the proposed transmission-based microwave glucose sensing, with a remarkable sensitivity of 1 ~ 1.5 dB for glucose level change up to 200 mg/dL.

Indexed as

Biosensing TechniquesBlood GlucoseBlood Glucose Self-MonitoringMachine LearningMicrowavesHumansBlood Glucose

Identifiers

PMID40346256
PMCPMC12064702

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.