A candidate reference measurement procedure for quantification of human insulin in serum based on immunoaffinity extraction and isotope dilution-liquid chromatography-tandem mass spectrometry.

Huixia Liu, Yanlin Han, Huimin Wang, Yuefeng Zhang, Chunlong Liu, Man Liang

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Huixia Liu *Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China.
Yanlin Han *Reference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China.
Huimin WangDepartment of Laboratory Medicine, Affiliated Hospital of Nantong University, Nantong, 226001, Jiangsu, China.
Yuefeng ZhangReference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China.
Chunlong LiuReference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China.
Man LiangReference Laboratory, Autobio Diagnostics Co., Ltd, Zhengzhou, 450016, Henan, China. liangman@autobio.com.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate measurement of human insulin is critical for proper diagnosis, monitoring, and treatment of diabetes. But the insulin results of clinical immunoassay are inconsistent mainly due to antibody cross-reactivity. To standardize and ensure the accuracy of clinical assays, reference measurement procedures (RMPs) with higher metrological order are required. An isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) for quantification of human insulin in serum as a candidate reference measurement procedure (cRMP) was developed and validated. Insulin was enriched from human serum by insulin antibodies immobilized on magnetic beads. The eluent was analyzed by ID-LC-MS/MS. The cRMP separated human insulin from potentially interfering compounds and enabled measurement over a range of 0.05-40 ng/g, with no matrix effects and carryover. The limit of detection (LOD) and the limit of quantitation (LOQ) in serum were 24.6 pg/g and 48.8 pg/g, respectively. Imprecision (intra-assay and inter-assay) was <2.77% at 0.436, 2.003, and 11.449 ng/g. Recoveries ranged from 99.5% to 101.7% at three spiked levels. Extraction recovery was measured at 85% or higher. Insulin analogues caused no interference for the determination of endogenous insulin. Expanded measurement uncertainty of target value-assigned samples was ≤3.5%. The cRMP was applied to measure human insulin in serum and was compared with two immunoassays using 46 serum samples. Also, a discrepancy of three candidate reference materials for the calibration of cRMP was discussed.

Indexed as

Chromatography, AffinityInsulinTandem Mass SpectrometryChromatography, LiquidHumansImmunoassayIndicator Dilution TechniquesLimit of DetectionReference StandardsReproducibility of ResultsInsulinCandidate reference measurement procedure (cRMP)DiabetesInsulinIsotope dilution-liquid chromatography-tandem mass spectrometry