ArticleSensors (Basel, Switzerland)2025
A Novel Inductive Displacement Sensor Based on Dual-Excitation and Single-Sensing Coils for Core Displacement Measurement.
Article in Sensors (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Digital Demodulation Method and Application of a PWM-Excited Differential Self-Inductive Displacement Transducer.Sensors (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
This article develops a new inductive displacement sensor with a segmented multi-group coil structure, which is suitable for the displacement measurement of control rods in nuclear reactors. Each group coil of the sensor consists of two excitation coils and one sensing coil. The excitation and sensing coils are segmented to extend the linearity range of the displacement sensor. It abandons the traditional sensor's method of using nonlinear compensation to achieve large-stroke displacement measurement. Providing an alternating current (AC) signal to the excitation coil and processing the induced voltage generated by each sensing coil can directly achieve the high-precision measurement of core displacement. The mathematical model of the variations in the sensing coil voltage caused by the movement of the core is established. The impacts of the excitation coil structure, the number of turns of the excitation coil, and the excitation frequency on the output characteristics of the designed sensor are analyzed by finite element simulation. Based on the analysis and design, a sensor prototype is built and tested in the laboratory. The measurement results show that the linearity error is 0.35% and the maximum measuring error can be limited within 1.5 mm, which is sufficient to meet the practical requirements in a nuclear reactor environment.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.