Evidence map›Paper›PMID 40371067›Full record

ArticleFrontiers in cardiovascular medicine2025

Isotropic, high-resolution, whole-chest inversion recovery contrast-enhanced magnetic resonance angiography in under 4.5 min using image-based navigator fluoro trigger.

Jason Craft, Roosha Parikh, Josh Y Cheng, Nancy Diaz, Karl P Kunze, Michaela Schmidt, Radhouene Neji, Amanda Leung, Suzanne Weber, Jonathan Weber and 6 more

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Feasibility and reproducibility of semi-automated magnetic resonance angiography measurements of the thoracic aorta using commercial software.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Jason CraftDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Roosha ParikhDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Josh Y ChengDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Nancy DiazDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Karl P KunzeMR Research Collaborations, Siemens Healthcare Limited, Camberley, United Kingdom.
Michaela SchmidtSiemens Healthineers, Erlangen, Germany.
Radhouene NejiSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Amanda LeungDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Suzanne WeberDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Jonathan WeberDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Timothy CarterDepartment of Cardiothoracic Surgery, Good Samaritan University Hospital, West Islip, NY, United States.
Sylvia BisoDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Ann-Marie YamashitaDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Eric H WolffDeMatteis Cardiovascular Institute, St. Francis Hospital & Heart Center, Roslyn, NY, United States.
Claudia PrietoSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.
Rene M BotnarSchool of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Serial assessment of the thoracic aorta with magnetic resonance angiography (MRA) is desirable due to 3D volumetric dataset, high spatial resolution, and lack of ionizing radiation. Electrocardiogram (ECG) gated, contrast-enhanced (CE), inversion recovery gradient echo MRA is efficient and historically provides low artifact burden, but the window for imaging with weak albumin binding extracellular gadolinium based contrast agents is small. Our purpose was to acquire whole-chest gated CE-MRA with 1.2 mm Methods: iNAV CE-MRA and TR-MRA were obtained prospectively in 40 patients and reviewed by 3 blinded cardiologists for vessel diameter and image quality rated on a four point scale: (1) non-diagnostic; (2) poor-significant blurring; (3) good-mild blurring; and (4) excellent. Reproducibility and image quality were evaluated using the concordance correlation statistic and Cohen's kappa with mean differences evaluated using paired Results: iNAV CE-MRA scan time was 4.2 ± 0.7 min. iNAV CE-MRA quality score was higher ( Conclusion: iNAV CE-MRA is feasible within a clinically reasonable scan time, provides superior image quality, and measurement reproducibility vs. TR-MRA.

Indexed as

image-based navigatormagnetic resonance angiographymotion correctiontime resolved angiographyvariable density sampling

Identifiers

PMID40371067
PMCPMC12075228

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.