Evidence map›Paper›PMID 40411715›Full record

ArticleEuropean radiology experimental2025

Improved image quality and reduced acquisition time in prostate T2-weighted spin-echo MRI using a modified PI-RADS-adherent sequence.

Stephen J Riederer, Eric A Borisch, Adam T Froemming, Roger C Grimm, Sara Hassanzadeh, Akira Kawashima, Naoki Takahashi, John Thomas

Abstract read
In one paragraph

Article in European radiology experimental, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Optimal Selection of the Effective Echo Time (TEJournal of magnetic resonance imaging : JMRI · 2026
    Article
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Stephen J RiedererDepartment of Radiology, Mayo Clinic, Rochester, MN, USA. riederer@mayo.edu.ORCID http://orcid.org/0000-0001-8045-910X
Eric A BorischDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Adam T FroemmingDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Roger C GrimmDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Sara HassanzadehDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Akira KawashimaDepartment of Radiology, Mayo Clinic, Phoenix, AZ, USA.
Naoki TakahashiDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
John ThomasDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.

Funding

EXTRAMURAL RES FACIL IMPROVEMENT PROG: POLYCYSTIC KIDNEY DISEASE, RENAL STUDIES,C06RR018898 · NCRR · MAYO CLINIC · PI BURNETT, JOHN C · 2004 to 2004
$2.3M
Super Resolution for Improved Multislice Prostate MRIR01EB031790 · NIBIB · MAYO CLINIC ROCHESTER · PI RIEDERER, STEPHEN J · 2022 to 2025
$2.3M
NCRR NIH HHS C06 RR018898NIBIB NIH HHS R01 EB031790
6 · The paper itself

Abstract

backgroundProstate imaging reporting and data system (PI-RADS) v2.1 guidelines for magnetic resonance imaging acquisition define a standard of 0.40 mm × 0.70 mm in-plane resolution (0.280 mm

methodsAn adherent T2WI sequence was modified by reducing the frequency sampling, thereby reducing the signal bandwidth (BW). This was compensated by increasing the phase sampling for an equivalent pixel area (0.50 mm × 0.57 mm = 0.285 mm

resultsIn the phantom, mean signal-to-noise ratios were equivalent for the two sequences; superior frequency resolution for the adherent sequence, and superior phase resolution for the modified sequence were shown. Across 62 participants, the median acquisition time was reduced by 23%, from 3:55 min:s to 3:01 min:s. For all three means of comparison (DQ, PI-QUALv2, reader preference), the modified sequence was significantly superior (p ≤ 0.037).

conclusionModification of the PI-RADS standard (0.40-mm frequency resolution) to an equivalent, more isotropic pixel area (0.28 mm RELEVANCE STATEMENT: Generalization of the PI-RADSv.2.1 minimum technical standard for T2WI in-plane resolution to be more isotropic preserves the targeted high resolution, allowing reduced acquisition time, also reducing motion sensitivity, and improving image quality. This approach may also reduce the need for rescanning poor-quality sequences. KEY POINTS: PI-RADSv2.1 suggests a standard T2WI sequence with 0.40 × 0.70 mm

Indexed as

Magnetic Resonance ImagingProstateProstatic NeoplasmsAgedHumansMaleMiddle AgedPhantoms, ImagingMagnetic resonance imagingPI-RADSProstateProstatic neoplasmsSignal-to-noise ratio

Identifiers

PMID40411715
PMCPMC12103434

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.