In one paragraph

Article in Journal of imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

George PapaioannouNew Bedford Research & Robotics, Downtown New Bedford, New Bedford, MA 02740, USA.ORCID 0009-0003-2580-7759
Christos MitrogiannisNew Bedford Research & Robotics, Downtown New Bedford, New Bedford, MA 02740, USA.
Mark SchweitzerOffice of the Vice President of Health Affairs, School of Medicine, Wayne State University, 1241 Scott Hall, 540 E. Canfield, Detroit, MI 48201, USA.
Nikolaos MichailidisSchool of Mechanical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.ORCID 0000-0002-4291-5327
Maria PappaSchool of Mechanical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.ORCID 0000-0003-2991-7456
Pegah KhosraviBiomedical AI, New York City College of Technology, Graduate Center, CUNY, 285 Jay Street, Brooklyn, NY 11201, USA.ORCID 0000-0003-3497-2820
Apostolos KarantanasDepartment of Medical Imaging, University Hospital, 71500 Heraklion, Greece.ORCID 0000-0002-0927-2403
Sean StarlingLevel 1, Meat and Livestock Australia, 40 Mount Street, P.O. Box 1961, North Sydney, NSW 2059, Australia.
Christian RubergLevel 1, Meat and Livestock Australia, 40 Mount Street, P.O. Box 1961, North Sydney, NSW 2059, Australia.

Funding

Intelligent Prosthetic Socket with Variable Volume and Elevated Vacuum SystemsR44HD068150 · NICHD · SMART SURFACE DESIGNS, LLC · PI PAPAIOANNOU, GEORGE · 2011 to 2012
$750k
Department of Health and Human Services National Institutes of Health EUNICE KENNEDY SHRIVER NATIONAL INSTITUTE OF CHILD HEALTH & HUMAN DEVELOPMENT-SBIR Award #R44 HD068150-01MLA Australian Government Meat and Livestock Australia Ltd 2019 Grants #P.PSH.0914 and #P.PSH.0915NICHD NIH HHS R44 HD068150US Army Medical Research and Material Command, DoD-TATRC Contract W81XWH-07-2-0113US Army Medical Research and Material Command, MOVE Center Award # 07-2-01
6 · The paper itself

Abstract

Characterizing imaging performance requires a multidisciplinary approach that evaluates various interconnected parameters, including dosage optimization and dynamic accuracy. Radiation dose and dynamic accuracy are challenged by patient motion that results in poor image quality. These challenges are more prevalent in the brain/cardiac pediatric patient imaging, as they relate to excess radiation dose that may be associated with various complications. Scanning vulnerable pediatric patients ought to eliminate anesthesia due to critical risks associated in some cases with intracranial hemorrhages, brain strokes, and congenital heart disease. Some pediatric imaging, however, requires prolonged scanning under anesthesia. It can often be a laborious, suboptimal process, with limited field of view and considerable dose. High dynamic accuracy is also necessary to diagnose tissue's dynamic behavior beyond its static structural morphology. This study presents several performance characterization experiments from a new robotic multimodal imaging system using specially designed calibration methods at different system configurations. Additional musculoskeletal imaging and imaging from a pediatric brain stroke patient without anesthesia are presented for comparisons. The findings suggest that the system's large dynamically controlled gantry enables scanning at full patient movement and with important improvements in scan times, accuracy, radiation dose, and the ability to image brain structures without anesthesia. This could position the system as a potential transformative tool in the pediatric interventional imaging landscape.

Indexed as

calibrationdynamic accuracymultimodalpediatric imagingradiation doserobotics-driven imaging devicestereovideoradiographytomosynthesisX-ray CT

Identifiers

PMID40423004
PMCPMC12112859

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.