Evidence map›Paper›PMID 40429147›Full record

ArticleMaterials (Basel, Switzerland)2025

Bioactive Glass and Melittin Thin Films Deposited by MAPLE for Titanium Implant Functionalization.

Mihaela Dinu, Bogdan Bita, Anca Constantina Parau, Carmen Ristoscu, Irina Negut

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Review
  2. Article
  3. Biocompatible Thin Films Deposited by Laser Techniques.Materials (Basel, Switzerland) · 2026
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mihaela DinuNational Institute of Research and Development for Optoelectronics-INOE2000, 409 Atomistilor St., 077125 Magurele, Romania.ORCID 0000-0002-3149-6972
Bogdan BitaNational Institute of Research and Development for Optoelectronics-INOE2000, 409 Atomistilor St., 077125 Magurele, Romania.ORCID 0000-0002-4102-635X
Anca Constantina ParauNational Institute of Research and Development for Optoelectronics-INOE2000, 409 Atomistilor St., 077125 Magurele, Romania.ORCID 0000-0002-4661-8362
Carmen RistoscuNational Institute for Laser, Plasma and Radiation Physics, 409 Atomistilor Street, P.O. Box MG 36, 077125 Magurele, Romania.ORCID 0000-0002-8433-9217
Irina NegutNational Institute for Laser, Plasma and Radiation Physics, 409 Atomistilor Street, P.O. Box MG 36, 077125 Magurele, Romania.ORCID 0000-0003-4038-7548

Funding

UEFISCDI PN-IV-P2-2.1-TE-2023-0993
6 · The paper itself

Abstract

The development of bioactive coatings for metallic implants is essential to enhance osseointegration and improve implant longevity. In this study, composite thin films based on bioactive glass and melittin were synthesized using the matrix-assisted pulsed laser evaporation technique and deposited onto titanium substrates. The coatings were characterized using physicochemical analysis methods, including scanning electron microscopy, atomic force microscopy, contact angle measurements, Fourier transform infrared spectroscopy, energy-dispersive X-ray spectroscopy, and electrochemical impedance spectroscopy. Simulated body fluid immersion tests were also conducted to assess bioactivity over time. Scanning electron microscopy and atomic force microscopy revealed dense, irregular surface textures with nanoscale features and an average roughness of ~120 nm, favorable for cell adhesion. Contact angle measurements showed a significant shift from hydrophobic (~95° for bare titanium) to moderately hydrophilic (~62° for the bioglass and melittin coating) surfaces, indicating improved biocompatibility. Electrochemical impedance spectroscopy demonstrated enhanced corrosion resistance in simulated body fluid, with the coating exhibiting a ~45% decrease in impedance magnitude after 12 h of immersion, compared to only 4% for bare titanium. Fourier transform infrared spectroscopy and energy-dispersive X-ray spectroscopy analyses confirmed the progressive formation of a carbonated apatite layer after 7 days of simulated body fluid exposure, suggesting high bioactivity and osteoconductive potential. The combined effects of bioactive glass and melittin in the thin film structure offer promising applications in orthopedic and dental implants, enhancing both biological performance and structural integrity.

Indexed as

bioglassbone regenerationmatrix-assisted pulsed laser evaporationmelittintitanium/orthopedic implants

Identifiers

PMID40429147
PMCPMC12113184

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.