ReviewAnnals of translational medicine2025
Optical coherence tomography retinal imaging: narrative review of technological advancements and clinical applications.
Review in Annals of translational medicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Retinal OCT Parameters and Physiological Dynamics as an Effect of Anesthesia in C57BL/6J Mice.Investigative ophthalmology & visual science · 2026Article
- Multi-scale adaptive fusion network for retinal layer and fluid segmentation in optical coherence tomography B-scans.Scientific reports · 2026Article
- Blood flow analysis of retinal neovascularisations in a VLDLR mouse model using contrast-enhanced optical coherence tomography.Biomedical optics express · 2026Article
- Spectral-Domain Optical Coherence Tomography Morphological Characteristics in Patients with Cone Dysfunction Disorders: A Retrospective Case Series.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Longitudinal Choriocapillaris and Retinal Vascular Flow Changes on OCTA with Progression to Advanced AMD.Clinical ophthalmology (Auckland, N.Z.) · 2025Article
- Adaptive Optics Imaging in Diabetic Retinopathy: A Comprehensive Review.Romanian journal of ophthalmologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background and Objective: Optical coherence tomography (OCT) is a non-invasive imaging tool that can provide rapid cross-sectional images of the retina, cornea, and optic nerve head in live patients. The objective of this review is to provide an overview of the technical advancements and current clinical applications of OCT for managing patients with retinal disorders. Methods: Narrative overview synthesizing the findings of literature retrieved from searches of computerized database, authoritative texts and authors' clinical experience and expertise. Key Content and Findings: Unlike the first-generation time-domain OCT (TD-OCT) instruments, the newer spectral-domain OCT (SD-OCT) instruments use a broadband light source to increase axial image resolution. In addition, the decreased image acquisition time also increases the transverse image resolution, reduces motion artifacts, and allows serial cross-sectional images of the retina to be obtained rapidly. A three-dimensional (3D) image of the retina, reconstructed using serial two-dimensional (2D) OCT images, can be used to quantitate retinal thickness and volume and perform analysis of retinal topography. Currently, commercial SD-OCT instruments are used routinely in clinical practice to obtain morphologic information used to diagnose and manage patients with various retinal disorders including macular degeneration and diabetic retinopathy. Newer swept-source OCT technology with faster image acquisition, provides wider field imaging of the peripheral retina. SD-OCT instruments can be incorporated into surgical microscopes to allow imaging of the retina during retinal surgery so that morphologic changes in the retina from surgical maneuvers can be observed in real time. More recently, OCT angiography (OCTA) has been developed which allows rapid, non-invasive 3D imaging of retinal and choroidal vascular flow. This is achieved by processing rapid serial SD-OCT images to detect movement of blood cells within vessels. Research has been done to further improve image resolution of SD-OCT to a cellular level by adding adaptive optics (AO) technology. The latest in SD-OCT technology is optoretinography (ORG), a technique to derive functional information from OCT images of the retina. Conclusions: Advancement in OCT technology has made it possible to obtain high resolution retinal images that can provide anatomic, physiologic and functional information of the retina in live patients.
Indexed as