Evidence map›Paper›PMID 40461985›Full record

ArticleBMC medical imaging2025

Multimodality comparison of aorta morphology in patients with aortopathy: 4D flow CMR, CTA, mDIXON.

Bastiaan J C Te Kiefte, Faeze Gholamiankhah, Joe F Juffermans, Pieter Van Den Boogaard, Arthur J H A Scholte, Hildo J Lamb, Jos J M Westenberg

Abstract readComparative Study
In one paragraph

Article in BMC medical imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bastiaan J C Te KiefteCardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands. b.j.c.te_kiefte@lumc.nl.
Faeze GholamiankhahCardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands.
Joe F JuffermansCardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands.
Pieter Van Den BoogaardCardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands.
Arthur J H A ScholteDepartment of Cardiology, Leiden University Medical Center (LUMC), Leiden, The Netherlands.
Hildo J LambCardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands.
Jos J M WestenbergCardio Vascular Imaging Group (CVIG), Leiden University Medical Center (LUMC), Leiden, The Netherlands.

Funding

Dutch Heart Foundation CVON2017-08-RADAREuropean Commission H2020-MSCA-ITN-2019-NOVA-MRI
6 · The paper itself

Abstract

backgroundFour-dimensional cardiovascular magnetic resonance flow imaging (4D flow CMR) enables analysing of aortic blood flow dynamics. In order to examine the relationship between morphology and hemodynamics, additional anatomical imaging is required. This study aims to assess if 4D flow CMR segmentations can be used to determine morphological parameters by comparing with segmentations from Computed Tomography Angiography (CTA) and mDIXON CMR.

methodsThis study included 18 patients with various aortic pathologies who underwent CTA and CMR (including mDIXON and 4D flow CMR sequences) of the thoracic aorta. The aortic lumen was segmented from aortic valve to the descending aorta and divided into four anatomical segments: aortic root [AoR], ascending aorta [AAo], aortic arch [AA], and descending aorta [DA]. We compared morphological parameters (maximum diameter, volume, and centreline length) using these different scanning techniques. Segmentations were performed at different cardiac phases: peak systole for CTA and 4D flow CMR, and end-diastole for mDIXON.

resultsIntraclass Correlation Coefficients (ICCs) and Bland-Altman plots were determined for all modalities and all segments. Agreement between 4D flow CMR and CTA was good to very good for maximum diameter (ICC 0.70-0.85) and centreline length (ICC 0.74-0.90), and very good to excellent for volume (ICC 0.89-0.97). Between mDIXON and CTA very good for maximum diameter (0.89-0.94), good to very good for centreline length (0.78-0.88), and very good to excellent for volume (0.87-0.96). Similar results were found when comparing 4D flow CMR with mDIXON with ICCs for maximum diameter (0.68-0.84), volume (0.91-0.97), and centreline length (0.78-0.90). Statistically significant differences were observed only for maximum diameter in AAo between CTA and mDIXON (p < 0.001), and for volume in AA between CTA and 4D flow CMR (p < 0.001). No significant differences were observed for other segments and parameters.

conclusionsMorphologic parameters derived from 4D flow CMR segmentations of the thoracic aorta demonstrate high levels of agreement when compared to segmentations based on CTA and mDIXON, in this relatively small cohort of patients with diverse aortic pathologies. This finding could be of interest for future 4D flow CMR research, as it possibly allows for the evaluation of both morphology and hemodynamics in a single imaging acquisition. Further research in larger cohorts is needed to robustly validate 4D flow CMR as a single-modality imaging technique.

Indexed as

AortaMultimodal ImagingAdultAgedComputed Tomography AngiographyFemaleHumansImage Processing, Computer-AssistedMagnetic Resonance ImagingMaleMiddle Aged4D flow CMRAortaCTAmDIXONMorphology

Identifiers

PMID40461985
PMCPMC12135574

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.