Evidence map›Paper›PMID 40558352›Full record

ArticleBiomimetics (Basel, Switzerland)2025

Comprehensive Stiffness Modeling and Evaluation of an Orthopedic Surgical Robot for Enhanced Cutting Operation Performance.

Heqiang Tian, Mengke Zhang, Jiezhong Tan, Zhuo Chen, Guangqing Chen

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Heqiang TianCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China.ORCID 0000-0002-9671-4862
Mengke ZhangCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
Jiezhong TanCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
Zhuo ChenCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
Guangqing ChenCollege of Mechanical and Electronic Engineering, Shandong University of Science and Technology, Qingdao 266590, China.

Funding

National Natural Science Foundation of China 52275496Shandong Provincial Natural Science Foundation ZR2024ME150
6 · The paper itself

Abstract

This study presents an integrated stiffness modeling and evaluation framework for an orthopedic surgical robot, aiming to enhance cutting accuracy and operational stability. A comprehensive stiffness model is developed, incorporating the stiffness of the end-effector, cutting tool, and force sensor. End-effector stiffness is computed using the virtual joint method based on the Jacobian matrix, enabling accurate analysis of stiffness distribution within the robot's workspace. Joint stiffness is experimentally identified through laser tracker-based displacement measurements under controlled loads and calculated using a least-squares method. The results show displacement errors below 0.3 mm and joint stiffness estimation errors under 1.5%, with values more consistent and stable than those reported for typical surgical robots. Simulation studies reveal spatial variations in operational stiffness, identifying zones of low stiffness and excessive stiffness. Compared to prior studies where stiffness varied over 50%, the proposed model exhibits superior uniformity. Experimental validation confirms model fidelity, with prediction errors generally below 5%. Cutting experiments on porcine femurs demonstrate real-world applicability, achieving average stiffness prediction errors below 3%, and under 1% in key directions. The model supports stiffness-aware trajectory planning and control, reducing cutting deviation by up to 10% and improving workspace stiffness stability by 30%. This research offers a validated, high-accuracy approach to stiffness modeling for surgical robots, bridging the gap between simulation and clinical application, and providing a foundation for safer, more precise robotic orthopedic procedures.

Indexed as

joint stiffness identificationorthopedic surgical robotstiffness distributionstiffness modelingvirtual joint method

Identifiers

PMID40558352
PMCPMC12190793

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked