Evidence map›Paper›PMID 40558796›Full record

ArticleJournal of imaging2025

Dose Reduction in Scintigraphic Imaging Through Enhanced Convolutional Autoencoder-Based Denoising.

Nikolaos Bouzianis, Ioannis Stathopoulos, Pipitsa Valsamaki, Efthymia Rapti, Ekaterini Trikopani, Vasiliki Apostolidou, Athanasia Kotini, Athanasios Zissimopoulos, Adam Adamopoulos, Efstratios Karavasilis

Abstract read
In one paragraph

Article in Journal of imaging, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Nikolaos BouzianisMedical Physics Laboratory, School of Medicine, Democritus University of Thrace, 69100 Alexandroupolis, Greece.ORCID 0009-0007-3282-7175
Ioannis Stathopoulos2nd Department of Radiology, Medical School, Attikon University Hospital, National and Kapodistrian University of Athens, 11527 Athens, Greece.ORCID 0000-0002-7769-7534
Pipitsa ValsamakiNuclear Medicine Department, University General Hospital of Alexandroupolis, Dragana, 69100 Alexandroupolis, Greece.
Efthymia RaptiNuclear Medicine Department, University General Hospital of Alexandroupolis, Dragana, 69100 Alexandroupolis, Greece.
Ekaterini TrikopaniMedical Physics Laboratory, School of Medicine, Democritus University of Thrace, 69100 Alexandroupolis, Greece.
Vasiliki ApostolidouNuclear Medicine Department, University General Hospital of Alexandroupolis, Dragana, 69100 Alexandroupolis, Greece.
Athanasia KotiniMedical Physics Laboratory, School of Medicine, Democritus University of Thrace, 69100 Alexandroupolis, Greece.ORCID 0000-0003-0575-8243
Athanasios ZissimopoulosNuclear Medicine Department, Medical School, Democritus University of Thrace, Dragana, 69100 Alexandroupolis, Greece.
Adam AdamopoulosMedical Physics Laboratory, School of Medicine, Democritus University of Thrace, 69100 Alexandroupolis, Greece.ORCID 0000-0001-6760-3971
Efstratios KaravasilisMedical Physics Laboratory, School of Medicine, Democritus University of Thrace, 69100 Alexandroupolis, Greece.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study proposes a novel deep learning approach for enhancing low-dose bone scintigraphy images using an Enhanced Convolutional Autoencoder (ECAE), aiming to reduce patient radiation exposure while preserving diagnostic quality, as assessed by both expert-based quantitative image metrics and qualitative evaluation.

methodsA supervised learning framework was developed using real-world paired low- and full-dose images from 105 patients. Data were acquired using standard clinical gamma cameras at the Nuclear Medicine Department of the University General Hospital of Alexandroupolis. The ECAE architecture integrates multiscale feature extraction, channel attention mechanisms, and efficient residual blocks to reconstruct high-quality images from low-dose inputs. The model was trained and validated using quantitative metrics-Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM)-alongside qualitative assessments by nuclear medicine experts.

resultsThe model achieved significant improvements in both PSNR and SSIM across all tested dose levels, particularly between 30% and 70% of the full dose. Expert evaluation confirmed enhanced visibility of anatomical structures, noise reduction, and preservation of diagnostic detail in denoised images. In blinded evaluations, denoised images were preferred over the original full-dose scans in 66% of all cases, and in 61% of cases within the 30-70% dose range.

conclusionThe proposed ECAE model effectively reconstructs high-quality bone scintigraphy images from substantially reduced-dose acquisitions. This approach supports dose reduction in nuclear medicine imaging while maintaining-or even enhancing-diagnostic confidence, offering practical benefits in patient safety, workflow efficiency, and environmental impact.

Indexed as

artificial intelligencebone scintigraphyconvolutional autoencoderdeep learningimage denoisinglow-dose imagingnuclear medicine

Identifiers

PMID40558796
PMCPMC12194355

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.