Evidence map›Paper›PMID 40579831›Full record

ArticleArtificial organs2025

New Findings on Pulsatile ECMO: Verification of the Potential to Improve Antithrombogenicity of a Membrane Oxygenator Using Pump-Generated Pulsatile Flow in an Innovative Animal Model.

Hironobu Sakurai, Tatsuki Fujiwara, Katsuhiro Ohuchi, Wataru Hijikata, Daiki Toda, Yui Tanaka, Orolzod Bumerdene, Sayaka Suzuki, Takehiro Iwanaga, Tomoyuki Fujita

Abstract read
In one paragraph

Article in Artificial organs, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hironobu SakuraiDepartment of Cardiovascular Surgery, Institute of Science Tokyo, Tokyo, Japan.ORCID https://orcid.org/0000-0003-3881-1979
Tatsuki FujiwaraDepartment of Cardiovascular Surgery, Institute of Science Tokyo, Tokyo, Japan.ORCID https://orcid.org/0000-0002-6931-1152
Katsuhiro OhuchiDepartment of Clinical Engineering, Juntendo University, Tokyo, Japan.ORCID https://orcid.org/0000-0002-8039-1296
Wataru HijikataDepartment of Mechanical Engineering, Institute of Science Tokyo, Tokyo, Japan.ORCID https://orcid.org/0000-0002-5433-1919
Daiki TodaDepartment of Mechanical Engineering, Institute of Science Tokyo, Tokyo, Japan.
Yui TanakaDepartment of Mechanical Engineering, Institute of Science Tokyo, Tokyo, Japan.
Orolzod BumerdeneDepartment of Cardiovascular Surgery, Institute of Science Tokyo, Tokyo, Japan.
Sayaka SuzukiTokyo Animal Cardiothoracic Surgery, Tokyo, Japan.
Takehiro IwanagaAnimal Research Facilities, Institute of Science Tokyo, Tokyo, Japan.
Tomoyuki FujitaDepartment of Cardiovascular Surgery, Institute of Science Tokyo, Tokyo, Japan.ORCID https://orcid.org/0000-0003-3023-5014

Funding

JSPS KAKENHI JP24K02528
6 · The paper itself

Abstract

backgroundExtracorporeal membrane oxygenation (ECMO) provides mechanical circulatory and respiratory support. However, thrombus formation in the circuit can lead to hemorrhagic complications, requiring improvements in ECMO anti-thrombogenicity. Few studies have reported the effect of pulsatile flow on thrombus formation in ECMO circuits. This study evaluated how pulsatile flow affects thrombus formation inside the membrane oxygenator.

methodsThis study was conducted in pigs (n = 5) using an experimental model in which each pig was connected to two different ECMO circuits: one with steady flow (via the jugular vein and carotid artery) and the other with pulsatile flow (via the femoral vein and artery). The pulsatile waveform was generated as an upward sinusoidal waveform added to the baseline frequency. Both circuits were set to a mean flow rate of 2 L/min and operated for 4 h without anticoagulation. Thrombus formation in the membrane oxygenators was observed during and after circulation. The thrombus area was quantified using image analysis.

resultsAll experiments were completed with stable hemodynamics. The pressure in the pulsatile circuit was confirmed to be a pulsatile waveform. The thrombus area in the steady flow circuits was 81.5%, 10.6%, 42.1%, 60.2%, and 96.7%, while those in the pulsatile flow circuits were 6.2%, 5.2%, 8.4%, 9.9%, and 65.8%, respectively. The thrombus area in the pulsatile flow circuit tended to be smaller than that in the steady flow circuit.

conclusionsPulsatile flow with a specific waveform may reduce thrombus formation in membrane oxygenators, potentially enhancing the anti-thrombogenicity of ECMO circuits.

Indexed as

Extracorporeal Membrane OxygenationOxygenators, MembranePulsatile FlowThrombosisAnimalsDisease Models, AnimalEquipment DesignHemodynamicsSwinedual extracorporeal circulationextracorporeal membrane oxygenatorpulsatile flowthrombus

Identifiers

PMID40579831
PMCPMC12760241

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.