Evidence map›Paper›PMID 40596595›Full record

ArticleScientific reports2025

3D printing of stents via two-photon polymerization.

Goda Grigorianaitė, Sergėjus Borodinas, Vilma Zigmantaitė, Karolina Limanovskaja, Dovilė Andrijec, Artūras Kilikevičius, Darius Vainorius, Arnoldas Pautienius, Linas Jonušauskas

Abstract read
In one paragraph

Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Goda GrigorianaitėVital3D Technologies, Saulėtekio Ave. 15, 10224, Vilnius, Lithuania. gg@vital3d.eu.
Sergėjus BorodinasDepartment of Applied Mechanics, Vilnius Gediminas Technical University, Saulėtekio Ave. 11, 10223, Vilnius, Lithuania.
Vilma ZigmantaitėDepartment of Anatomy and Physiology, Faculty of Veterinary Medicine, Lithuanian University of Health Sciences, Tilžės Str. 18, 47181, Kaunas, Lithuania.
Karolina LimanovskajaVital3D Technologies, Saulėtekio Ave. 15, 10224, Vilnius, Lithuania.
Dovilė AndrijecVital3D Technologies, Saulėtekio Ave. 15, 10224, Vilnius, Lithuania.
Artūras KilikevičiusMechanical Science Institute, Vilnius Gediminas Technical University, Plytinės Str. 25, 10105, Vilnius, Lithuania.
Darius VainoriusMechanical Science Institute, Vilnius Gediminas Technical University, Plytinės Str. 25, 10105, Vilnius, Lithuania.
Arnoldas PautieniusDepartment of Anatomy and Physiology, Faculty of Veterinary Medicine, Lithuanian University of Health Sciences, Tilžės Str. 18, 47181, Kaunas, Lithuania.
Linas JonušauskasVital3D Technologies, Saulėtekio Ave. 15, 10224, Vilnius, Lithuania.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stents are medical devices used to treat the narrowing of the blood vessel, most commonly caused by atherosclerosis. Currently used bare-metal, drug-eluting stents are limited in size and architectural complexity, and there are a few risks associated with these medical devices. In some cases stents can cause thrombosis or even death. Furthermore, said risk increases while stenting relatively small vessels. This paper shows that vascular stents for relatively small vessels and/or for patient-specific stenting applications can be printed using two-photon polymerization (2PP). 2PP is an additive manufacturing technique with sub-μm resolution and unlimited 3D geometry potential. These capabilities were used to produce stents for small blood vessels, which are 5 mm tall and 0.7 or 0.9 mm in diameter, with 3D struts as thin as 50 μm. Several novel approaches were introduced to accommodate the printing of such a structure like voxel elongation and printing in stereolithography-like vat-sample holder configuration. Furthermore, the produced stents were tested mechanically proving their mechanical resilience to most common types of mechanical deformations. Experimental results were also compared to mathematical modeling, showing excellent agreement, hinting at the possibility of designing and testing complex micro-stent geometries before fabrication in silico. Finally, biocompatibility experiments were performed, in which rats survived the 7-day incubation period and showed no significant biocompatibility issues. Overall, the presented work gives an outlook on all aspects related to the 3D printing of stents - design, manufacturing, mechanical, and biological testing. We show that 2PP aligns very well with all these aspects and is a promising technique for the mass manufacturing of vascular stents for small vessels or specifically for the patient.

Indexed as

PhotonsPolymerizationPrinting, Three-DimensionalStentsAnimalsDrug-Eluting StentsHumansMaterials TestingRats

Identifiers

PMID40596595
PMCPMC12214932

What Socratic holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.