Dual-Center Repeatability, Consistency, and Comparison of 3D Phase-Resolved Functional (PREFUL) Ventilation MRI at 3 and 1.5 T in Healthy Volunteers.
Article in NMR in biomedicine, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Feasibility of quantitative pulmonary function imaging in real-world cardiovascular magnetic resonance.The international journal of cardiovascular imaging · 2026Article
- Comparison of Signal- and Volume-Based Ventilation-Weighted Assessment Using 3D FLORET UTE MRI in Patients With Various Pulmonary Disease.Magnetic resonance in medicine · 2026Article
- Comparing the Perfusion and Functional Assessment Capabilities of Electrocardiography- and Photoplethysmography-monitored Phase-resolved Functional Lung and Dynamic Contrast-enhanced Perfusion MR Imaging.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2026Article
- Article
- Dual-Center Repeatability, Consistency, and Comparison of 3D Phase-Resolved Functional (PREFUL) Ventilation MRI at 3 and 1.5 T in Healthy Volunteers.NMR in biomedicine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
3D phase-resolved functional lung (PREFUL) MRI offers lung ventilation assessment without contrast and in free breathing. However, there are limited data on its repeatability and intercenter consistency. This study aimed to assess the repeatability and intercenter consistency of 3D PREFUL MRI at two centers using both 3- and 1.5-T field strengths. Fifty healthy volunteers (35 female, 70%; median age 25.5 [interquartile range 22.3-29.0 years]) participated in this prospective study. A golden-angle stack-of-stars spoiled gradient echo acquisition was used for 3D PREFUL MRI. To assess for repeatability, 3D PREFUL MRI was performed twice with a short interval between scans at each center. At Center 1, scans were performed at 3 and 1.5 T. At Center 2, scans were performed at 3 T. Intercenter consistency of 3D PREFUL MRI was assessed between centers at 3 T. Performance of 3D PREFUL MRI at 3 and 1.5 T was compared at Center 1. Bland-Altman analysis, coefficient of variation, intraclass correlation coefficient, and Cohen's d were used for the repeatability assessment. Similarly, interfield strength and intercenter differences were quantified by Bland-Altman analysis. In all comparisons, paired Wilcoxon signed-rank test was used to examine differences. 3D PREFUL MRI parameters showed no significant differences between repeated measurements across three scanners, except for mean regional ventilation (RVent) at Center 2 (p = 0.0046). Apart from mean RVent during the second measurement (p = 0.03) and tidal volume during both measurements (both p < 0.02), no significant differences were found between 3D PREFUL MRI parameters at 3 T across both centers. Output parameters were significantly different when images were acquired using 3 T compared to 1.5 T (all p < 0.0093). 3D PREFUL MRI ventilation-weighted parameters showed fair to excellent repeatability and consistent intercenter results. Given the significant differences in outputs acquired using scanners of different field strengths, multicenter studies should be conducted with scanners of the same field strength.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.