Evidence map›Paper›PMID 40710235›Full record

ArticleBiomimetics (Basel, Switzerland)2025

Design of a Hierarchical Control Architecture for Fully-Driven Multi-Fingered Dexterous Hand.

Yinan Jin, Hujiang Wang, Han Ge, Guanjun Bao

Abstract read
In one paragraph

Article in Biomimetics (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yinan JinCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China.ORCID 0000-0003-0439-8485
Hujiang WangCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China.ORCID 0009-0000-7905-7867
Han GeCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China.
Guanjun BaoCollege of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China.ORCID 0000-0002-7184-3510

Funding

Natural Science Foundation of Zhejiang Province (CN) LZ23E050005, LMS25E050008
6 · The paper itself

Abstract

Multi-fingered dexterous hands provide superior dexterity in complex manipulation tasks due to their high degrees of freedom (DOFs) and biomimetic structures. Inspired by the anatomical structure of human tendons and muscles, numerous robotic hands powered by pneumatic artificial muscles (PAMs) have been created to replicate the compliant and adaptable features of biological hands. Nonetheless, PAMs have inherent nonlinear and hysteresis behaviors that create considerable challenges to achieving real-time control accuracy and stability in dexterous hands. In order to address these challenges, this paper proposes a hierarchical control architecture that employs a fuzzy PID strategy to optimize the nonlinear control of pneumatic artificial muscles (PAMs). The FPGA-based hardware integrates a multi-channel digital-to-analog converter (DAC) and a multiplexed acquisition module, facilitating the independent actuation of 20 PAMs and the real-time monitoring of 20 joints. The software implements a fuzzy PID algorithm that dynamically adjusts PID parameters based on both the error and the error rate, thereby effectively managing the nonlinear behaviors of the hand. Experimental results demonstrate that the designed control system achieves high precision in controlling the angle of a single finger joint, with errors maintained within ±1°. In scenarios involving multi-finger cooperative grasping and biomimetic motion demonstrations, the system exhibits excellent synchronization and real-time performance. These results validate the efficacy of the fuzzy PID control strategy and confirm that the proposed system fulfills the precision and stability requirements for complex operational tasks, providing robust support for the application of PAM-driven multi-fingered dexterous hands.

Indexed as

fuzzy PIDmulti-fingered dexterous handpneumatic artificial muscles

Identifiers

PMID40710235
PMCPMC12292831

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.