Evidence map›Paper›PMID 40731567›Full record

ArticleMaterials (Basel, Switzerland)2025

Novel Customizable Fracture Fixation Technique vs. Conventional Metal Locking Plate: An Exploratory Comparative Study of Fixation Stability in an Experimental In Vivo Ovine Bilateral Phalangeal Fracture Model.

Thomas Colding-Rasmussen, Nanett Kvist Nikolaisen, Peter Frederik Horstmann, Michael Mørk Petersen, Daniel John Hutchinson, Michael Malkoch, Stine Jacobsen, Christian Nai En Tierp-Wong

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Thomas Colding-RasmussenDepartment of Orthopaedic Surgery, Rigshospitalet, University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark.ORCID 0000-0003-3457-3715
Nanett Kvist NikolaisenDepartment of Orthopaedic Surgery, Hvidovre University Hospital, Kettegaard Alle 36, 2650 Copenhagen, Denmark.ORCID 0000-0003-3481-1226
Peter Frederik HorstmannDepartment of Orthopaedic Surgery, Herlev-Gentofte University Hospital, Gentofte Hospitalsvej 1, 2900 Copenhagen, Denmark.
Michael Mørk PetersenDepartment of Orthopaedic Surgery, Rigshospitalet, University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark.ORCID 0000-0002-2324-6420
Daniel John HutchinsonDepartment of Fibre and Polymer Technology, KTH Royal Institute of Technology, Brinellvägen 8, 114 28 Stockholm, Sweden.ORCID 0000-0003-0028-1204
Michael MalkochDepartment of Fibre and Polymer Technology, KTH Royal Institute of Technology, Brinellvägen 8, 114 28 Stockholm, Sweden.ORCID 0000-0002-9200-8004
Stine JacobsenDepartment of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Agrovej 8, 2630 Copenhagen, Denmark.ORCID 0000-0002-2380-4576
Christian Nai En Tierp-WongDepartment of Orthopaedic Surgery, Rigshospitalet, University Hospital, Blegdamsvej 9, 2100 Copenhagen, Denmark.ORCID 0000-0002-3201-5827

Funding

by European Union's Horizon 2020 research and innovation program 952150
6 · The paper itself

Abstract

A novel composite patch osteosynthesis technique (CPT) has demonstrated promising ex vivo biomechanical performance in small tubular bones. To bridge the gap toward clinical evaluations, this study compared the stability of the CPT to a stainless-steel locking plate (LP) in an experimental in vivo ovine bilateral proximal phalanx fracture model. Eight sheep underwent a midline osteotomy with a 4.5 mm circular unicortical defect in the lateral proximal phalanx of both front limbs, treated with the CPT (n = 8) or the LP (n = 8). A half-limb walking cast, or a custom off-loading hoof shoe, was used for postoperative protection. Implant stability was assessed by post-surgery X-ray evaluations and post-euthanasia (16 weeks) dual-energy X-ray absorptiometry (DXA). At week one, all CPT implants demonstrated mechanical failure, while all LPs remained overall intact. Mean BMD was 0.45 g/cm

Indexed as

biomechanical stabilityfracture fixationin vivo ovine fracture model

Identifiers

PMID40731567
PMCPMC12298223

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.