Evidence mapPaperPMID 40737124Full record

ArticleACS sensors2025

Superparamagnetic Bead-Based Microfluidic Fluoroimmunoassay Platform for Rapid Ochratoxin A Detection in Flour.

Daniel López-Puertollano, Charlie Tobias, Jérémy Bell, Antonio Abad-Somovilla, Antonio Abad-Fuentes, Knut Rurack

Abstract read
In one paragraph

Article in ACS sensors, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Daniel López-PuertollanoChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin 12489, Germany.ORCID 0000-0001-7259-4918
Charlie TobiasChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin 12489, Germany.ORCID 0000-0003-2440-3181
Jérémy BellChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin 12489, Germany.ORCID 0000-0003-1861-1670
Antonio Abad-SomovillaDepartment of Organic Chemistry, University of Valencia, Doctor Moliner 50, Burjassot, Valencia 46100, Spain.ORCID 0000-0002-5599-3682
Antonio Abad-FuentesInstitute of Agricultural Chemistry and Food Technology (IATA), Spanish Council for Scientific Research (CSIC), Av. Agustí Escardino 7, Paterna, Valencia 46980, Spain.ORCID 0000-0001-5672-1438
Knut RurackChemical and Optical Sensing Division, Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, Berlin 12489, Germany.ORCID 0000-0002-5589-5548

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Simplification and reduction of time and costs are the primary goals in the development and use of onsite methods in diagnostics and food safety. To facilitate the transition from laboratory techniques to simple, miniaturized devices, we have developed a modular microfluidic platform. This platform integrates a competitive fluorescence immunoassay on the surface of superparamagnetic beads, serving as a complementary technique to traditional cytometry assays. In the first chip module, a fast competitive reaction (5 min) occurs, after which the particles are retained in the second module. This module consists of a PDMS chip and a permanent magnet, allowing only the fluorescent competitor to reach the detection module. Ochratoxin A (OTA) was chosen as the model analyte for device development, using fluorescein-labeled OTA as a competitor. The system efficiently separates particles, with OTA concentration directly correlated to the amount of fluorescent competitor remaining in solution after the competitive reaction. This innovative setup allows to perform rapid measurements with small sample volumes in a short time (10 min), achieving a limit of detection for OTA of 1.2 μg L

Indexed as

FlourMicrofluidic Analytical TechniquesOchratoxinsFluoroimmunoassayFood ContaminationLimit of Detectionochratoxin AOchratoxinsbead-based assayfluorescenceimmunoassaymicrofluidicsmycotoxins

Identifiers

PMID40737124
PMCPMC12379180

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.