Fixation method influences FLASH skin sparing in an in vivo leg model.

Line Kristensen, Cathrine Overgaard, Jacob Johansen, Anna Hansen, Niels Bassler, Per Poulsen, Brita Sørensen

Abstract read
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Line KristensenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark. line.kristensen@clin. au.dk.ORCID 0000-0003-0924-475X
Cathrine OvergaardDepartment of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.ORCID 0000-0002-8546-2735
Jacob JohansenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
Anna HansenDepartment of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
Niels BasslerDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.ORCID 0000-0002-4160-1078
Per PoulsenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.
Brita SørensenDanish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark; Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Medicine, Aarhus University, Aarhus, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeThe FLASH effect, where ultra-high dose rate elicits a favourable normal tissue-sparing, has been shown in several preclinical studies. Study setup differences, for example fixation methods that affect blood flow, can influence radiation response but are unexplored for FLASH. This study compared FLASH's acute skin-sparing effect with two fixation methods: a glued fixation (no blood flow restriction) and taped fixation (slight blood flow restriction). Patient/material and methods: Female CDF1 mice were irradiated on their hind foot using a glue-fixation or tape-fixation method. Glue-fixated mice were only taped during the glueing procedure and had a 10-min unrestricted period afterwards before irradiation, while tape-fixated mice were taped shortly before and throughout irradiation. Mice received single-dose irradiation (19-58 Gy) with either conventional dose rate (CONV, protons 0.06 Gy/s, electrons 0.16 Gy/s) or FLASH (electrons, 223-233 Gy/s). Differences in skin toxicity were analysed.

resultsCONV-treated tape-fixated mice required a 16-17% higher dose to induce skin toxicity relative to glued mice for both protons and electrons. Meanwhile, the fixation method did not affect FLASH-treated mice. The resulting electron FLASH-sparing effect was reduced by 18% due to the shift in radiosensitivity for CONV-treated mice.

interpretationCONV-treated tape-fixated mice were more radioresistant than the glue-fixated mice, consistent with the expected response to mild hypoxia. FLASH-treated mice were unaffected. These findings demonstrate the impact of fixation and, in turn, oxygen level on the differential CONV versus FLASH skin response. The results highlight the importance of minimal systemic influence on animals during FLASH studies.

Indexed as

Organ Sparing TreatmentsSkinAnimalsFemaleHindlimbMice

Identifiers

PMID40762144
PMCPMC12340987