Evidence map›Paper›PMID 40785470›Full record

ArticleSmall (Weinheim an der Bergstrasse, Germany)2025

Conducting Atomic Force Microscopy of Protein Wires.

Brian Ashcroft, Stuart Lindsay

Abstract read
In one paragraph

Article in Small (Weinheim an der Bergstrasse, Germany), 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Brian AshcroftBiodesign Institute, Arizona State University, Tempe, AZ, 85287, USA.
Stuart LindsayBiodesign Institute, Arizona State University, Tempe, AZ, 85287, USA.ORCID 0000-0002-9364-6542

Funding

Sequencing by Direct Electrical Measurements of Polymerase FluctuationsR01HG011079 · NHGRI · ARIZONA STATE UNIVERSITY-TEMPE CAMPUS · PI LINDSAY, STUART · 2020 to 2022
$1.8M
NHGRI NIH HHS R01 HG011079
6 · The paper itself

Abstract

Scanning tunneling microscopy (STM) studies have shown that protein wires based on the consensus tetratricopetide repeat (CTPR) conduct with an electrical resistance proportional to length of the protein, consistent with long-range hopping transport along the long axis of the protein. However, the attempts to measure similar currents across proteins mounted in fixed-gap devices have not been successful. Here, the study reports conducting atomic force microscopy studies of CTPR8 and CTPR4, ≈8 and 4 nm in length, finding that substantial contact force (>50 nN) is required to observe conduction in CTPR8. Scrape-tests indicate that the probe penetrates the film by ≈1 nm at this force. Importantly, electrical contacts that resemble the STM data are rare-approximately 1% of all contacts. STM reports only successful contacts, so it does not predict statistically how the proteins will behave in a fixed junction.

Indexed as

Microscopy, Atomic ForceProteinsMicroscopy, Scanning TunnelingProteinsconducting AFMconsensustetratricopeptidemolecular electronicsprotein electronicsprotein wires

Identifiers

PMID40785470
PMCPMC12380426

What Socratic holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.