Evidence map›Paper›PMID 40793819›Full record

Observational studyJMIR mHealth and uHealth2025

Comparison of ActiGraph CentrePoint Insight Watch Placement on Dominant and Nondominant Wrists in Young Adults in Free-Living Conditions: Observational Validation Study.

Daehyoung Lee, Haley Voermans-Dean, Jung Eun Lee, Jong Cheol Shin, Gregory Dominick

Abstract readObservational StudyValidation Study
In one paragraph

Observational study in JMIR mHealth and uHealth, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Daehyoung LeeDepartment of Health Behavior and Nutrition Sciences, University of Delaware, 26 North College Avenue (013 Carpenter Sports Building), Newark, Delaware, 19716, United States, 1 302 831 0762.ORCID 0000-0001-6194-7474
Haley Voermans-DeanDepartment of Applied Human Sciences, University of Minnesota Duluth, Duluth, Minnesota, United States.ORCID 0009-0006-2838-9873
Jung Eun LeeDepartment of Applied Human Sciences, University of Minnesota Duluth, Duluth, Minnesota, United States.ORCID 0000-0002-8770-0901
Jong Cheol ShinDepartment of Community and Population Health, Lehigh University, Bethlehem, PA, United States.ORCID 0000-0003-0360-2309
Gregory DominickDepartment of Health Behavior and Nutrition Sciences, University of Delaware, 26 North College Avenue (013 Carpenter Sports Building), Newark, Delaware, 19716, United States, 1 302 831 0762.ORCID 0000-0001-6256-503X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: With the continuous evolution of technology, wearable accelerometers have become one of the most popular means of measuring daily physical activity (PA) levels. Despite the conventional use of the nondominant wrist as a device placement in numerous PA studies, the impact of wrist-worn accelerometer placement on PA data outcomes remains uncertain. Objective: This study aimed to examine the degree of agreement between accelerometry data collected from CentrePoint Insight Watches (CPIWs; ActiGraph) worn on the dominant and nondominant wrists of young adults in free-living conditions. Methods: Twenty-nine participants (mean age 20.2, SD 1.6 years; 23 females) simultaneously wore an ActiGraph CPIW on both dominant and nondominant wrists for 7 consecutive days during waking hours. A sampling frequency of 32 Hz and Montoye 2020 cut-points were used to categorize activity intensity based on counts per minute. Data validity criteria included (1) ≥600 minutes per day of monitor wear time for both wrists, (2) a daily wear time difference of <1% of the average wear time between the dominant and nondominant wrists, and (3) a minimum of 3 valid days of monitor wear for both wrists. Bland-Altman plots and intraclass correlation coefficient (ICC) analyses were performed to compare the accelerometry data between the two device placements. Results: Average daily monitor wear time was 789.6 (SD 86.1) minutes per day for the dominant wrist and 793.0 (SD 91.8) minutes per day for the nondominant wrist. All accelerometer variables, including sedentary time (ST), light PA, moderate-to-vigorous PA (MVPA), steps, triaxial counts, and vector magnitude (VM), showed good-to-excellent levels of reliability between the two measurements (ICC >0.88 for all; P<.001). Bland-Altman analysis calculated mean bias and SD between the two device placements as follows: ST (-18.8, SD 27.6 min/d), light PA (2.7, SD 15.9 min/d), MVPA (12.7, SD 26.7 min/d), steps (218.1, SD 476.6 counts/d), x-axis (99.4, SD 188.8 counts/min), y-axis (73.9, SD 147.0 counts/min), z-axis (107.6, SD 183.5 counts/min), and VM (161.2, SD 273.4 counts/min). Bland-Altman plots revealed that the upper and lower limits of agreement across most variables were considerably wide. Conclusions: Our findings partially align with previous research, demonstrating higher MVPA and step counts on the dominant wrist, while the nondominant wrist produced a higher level of ST. Despite the acceptable level of reliability between the two placements based on ICC analyses, the dominant wrist tended to produce greater outcomes as the intensity of PA increased, highlighting the need for careful consideration when determining the wear location of CPIWs and interpreting data outcomes.

Indexed as

AccelerometryActigraphyWristAdultExerciseFemaleHumansIndependent LivingMaleReproducibility of ResultsWearable Electronic DevicesYoung Adultdevice placementmeasurementphysical activitysedentary timewrist-worn accelerometry

Identifiers

PMID40793819
PMCPMC12338961

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.