ArticleScientific reports2025
Hyperspectral magnetite grade based on characteristic band screening inversion study.
Article in Scientific reports, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In order to clarify the relationship between magnetite grade and reflectance spectra, spectral testing of different grades of magnetite was carried out to analyze the effect of iron grade on the reflectance spectra of specimens. The results show that the fluctuation trends of the spectral curves of different grades of magnetite are slightly different. By screening the characteristic bands of magnetite grade, it was found that the characteristic bands of different grades of magnetite are mainly distributed in the range of 350-1000 nm and 1800-2500 nm. Then based on the relationship between magnetite grade and reflectance spectra, two inversion models of magnetite grade, PLSR(Partial Least Squares Regression) and MLSR(Multiple Linear Stepwise Regression), were established. By comparing and analyzing the inversion models of magnetite grade established by PLSR and MLSR, it was found that the inversion accuracy based on the PLSR model was better than that of the MLSR model, in which the [Formula: see text] and the RMSE of validation set of the best model was respectively 0.9982 and 0.95%.
Indexed as
Identifiers
What Socratic holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.