Evidence map›Paper›PMID 40828523›Full record

ArticleTranslational vision science & technology2025

Near Visual Acuity Measurements by Community Screeners Using Digital (Peek) Testing Versus Conventional Charts in India.

Shalinder Sabherwal, Mohd Javed, Elanor Watts, Marzieh Katibeh, Alice Pintus, Nam Thaker, Sergio Latorre-Arteaga, Vince Hewitt, Darren Coverley, Nigel M Bolster and 1 more

Abstract readComparative Study
In one paragraph

Article in Translational vision science & technology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Shalinder SabherwalDepartment of Community Ophthalmology and Public Health Research, Dr. Shroff's Charity Eye Hospital, New Delhi, India.
Mohd JavedDr. Shroff's Charity Eye Hospital, New Delhi, India.
Elanor WattsPeek Vision, Berkhamsted, UK.
Marzieh KatibehPeek Vision, Berkhamsted, UK.
Alice PintusPeek Vision, Berkhamsted, UK.
Nam ThakerPeek Vision, Berkhamsted, UK.
Sergio Latorre-ArteagaPeek Vision, Berkhamsted, UK.
Vince HewittPeek Vision, Berkhamsted, UK.
Darren CoverleyPeek Vision, Berkhamsted, UK.
Nigel M BolsterInternational Centre for Eye Health, London School of Hygiene and Tropical Medicine, London, UK.
Andrew BastawrousInternational Centre for Eye Health, London School of Hygiene and Tropical Medicine, London, UK.

Funding

Wellcome Trust
6 · The paper itself

Abstract

Purpose: The Peek digital near vision test has been previously validated in a trial setting; here it is assessed in clinic (stage 1) and community (stage 2) settings. Methods: The study was carried out in the catchment area of Dr. Shroff's Charity Eye Hospital, Mohammadi, Uttar Pradesh, India, with a total of 768 participants. Stage 1 assessed the interobserver variability of Peek near vision impairment (NVI) screening in 168 clinic participants, with three trained community screeners. Stage 2 compared Peek to conventional chart testing for NVI screening using Cohen's kappa coefficient, sensitivity, and specificity and, for quantitative near visual acuity (NVA) measurement, using Bland-Altman limits of agreement (LoA) in 600 participants with two screeners. Results: In stage 1, interobserver variability using Peek ranged from 96.43% to 98.21% (kappa = 0.92-0.96). In stage 2, there was overall agreement in 95.8% of cases (kappa = 0.91). Peek testing had a sensitivity and specificity of 91.25% (95% confidence interval [CI], 87.22-94.1) and 99.41% (95% CI, 97.86-99.84), respectively. For NVA testing, the 95% LoA between Peek and chart testing were within -0.11 and +0.07 logMAR. Mean test time was 40.3 seconds (95% CI, 38.8-41.7) for Peek versus 46.6 seconds (95% CI, 45.5-47.7) for a conventional chart. Conclusions: The previously demonstrated validity of Peek testing was maintained when used by trained community screeners. Translational Relevance: The Peek near vision test can be used as a validated method of NVA/NVI measurement in research, clinical and community settings.

Indexed as

Vision DisordersVision ScreeningVision TestsVisual AcuityAdolescentAdultAgedFemaleHumansIndiaMaleMiddle AgedObserver VariationReproducibility of ResultsSensitivity and SpecificityYoung Adult

Identifiers

PMID40828523
PMCPMC12369907

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.