Evidence map›Paper›PMID 40879303›Full record

ArticleJournal of applied clinical medical physics2025

A self-gated 4D-MRI sequence for internal target volume delineation in liver: Phantom and pre-clinical validation.

Shuoyan Chen, Muyu Liu, Shaobo Xue, Yiling Zeng, Bo Pang, Qi Zhang, Xuewen Hou, Hongcheng Yang, Ziyun Guan, Hong Quan and 2 more

Abstract readValidation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Shuoyan ChenDepartment of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China.ORCID https://orcid.org/0009-0002-1752-3468
Muyu LiuDepartment of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China.
Shaobo XueCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Yiling ZengDepartment of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China.
Bo PangDepartment of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China.
Qi ZhangDepartment of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China.
Xuewen HouShanghai United Imaging Healthcare Co., Ltd, Shanghai, China.ORCID https://orcid.org/0000-0001-9828-4926
Hongcheng YangShanghai United Imaging Healthcare Co., Ltd, Shanghai, China.ORCID https://orcid.org/0009-0003-3451-6857
Ziyun GuanShanghai United Imaging Healthcare Co., Ltd, Shanghai, China.
Hong QuanDepartment of Medical Physics, School of Physics and Technology, Wuhan University, Wuhan, China.
Changli RuanDepartment of Radiation Oncology, Renmin Hospital, Wuhan University, Wuhan, China.
Zhiyong YangCancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe poor soft tissue resolution of four-dimensional computed tomography (4D-CT) limits its utility in delineating liver cancer target volumes. PURPOSE: To compare the consistency between four-dimensional magnetic resonance imaging (4D-MRI) using T1-weighted (T1w) radial stack-of-stars (SOS) gradient echo (GRE) sequences and 4D-CT in assessing tumor motion and morphology, for defining internal target volume in liver tumor radiotherapy. MATERIALS AND

methodsPosition and geometric accuracy and the impact of baseline drift between 4D-MRI (using T1w radial SOS GRE sequence) and 4D-CT were evaluated using a motion phantom. Ten primary liver cancer patients were included for comparison. Volume, centroid position, dice similarity coefficient (DSC), and 95% Hausdorff distance (HD95) were assessed.

resultsBaseline drift did not significantly affect target motion or morphology descriptions in 4D-MRI (normal vs. drift: p = 0.139, DSC = 0.94 ± 0.01, HD95 = 1.82 ± 0.43) or 4D-CT (p = 0.051, DSC = 0.95 ± 0.03, HD95 = 1.59 ± 0.71), but significantly impacted target volume delineation (4D-CT: p = 0.040; 4D-MRI: p = 0.024). Phantom studies showed consistent motion amplitude measurements between modalities for small motion patterns (2 s/10 mm; p = 0.192), while 4D-MRI underestimated amplitudes in large patterns (4 s/20 mm; p = 0.012), consistent with patient data (small: p = 0.453; large: p = 0.004). Volume analysis revealed 4D-MRI underestimated phantom volumes by 6.33% (2 s/10 mm) and 6.10% (4 s/20 mm) versus ground truth, contrasting with 4D-CT's overestimations (2.01% and 2.51%). Clinically, 4D-CT-derived gross tumor volumes (GTVs)/internal tumor volumes (ITVs) exceeded 4D-MRI measurements, particularly in large motion patterns (GTVs: (11.79 ± 13.13)%; ITVs: (22.08 ± 18.59)%) versus small patterns (GTVs: (9.70 ± 9.10)%; ITVs: (11.01 ± 8.05)%). Temporal stability metrics were comparable between modalities for small motion (phantom DSC p = 0.770, HD95 p = 0.131; patient DSC p = 0.156), with overall GTV/ITV spatial agreement (DSC: 0.79 ± 0.06 vs. 0.83 ± 0.04 for 4D-CT vs. 4D-MRI).

conclusionThe results show 4D-MRI with a T1w radial SOS GRE sequence matches 4D-CT's accuracy in target motion characterization and morphological delineation, while providing precise tumor delineation for primary liver cancer patients.

Indexed as

Four-Dimensional Computed TomographyImage Processing, Computer-AssistedLiver NeoplasmsMagnetic Resonance ImagingPhantoms, ImagingRadiotherapy Planning, Computer-AssistedFemaleHumansMaleRadiotherapy DosageRadiotherapy, Intensity-Modulatedfour‐dimensional computed tomographyfour‐dimensional magnetic resonance imagingliver cancerphantomradiotherapyrespiratory motion

Identifiers

PMID40879303
PMCPMC12395459

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.