An Infrared Non-Invasive System for Measuring Blood Glucose: A Primary Study using Serum Samples.
Article in Journal of biomedical physics & engineering, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Diabetes is a global concern, with an estimated 2 million individuals expected to be affected by the condition by 2024. Non-invasive glucose monitoring devices can greatly enhance patient care and management. Objective: This study aimed to develop an instrument capable of non-invasively measuring blood glucose levels using an infrared transmitter and receiver, with data processing performed by a dedicated processor. Material and Methods: This analytical study develops a glucometer that incorporates a power supply, a light source, a light detector, a sampler, and signal processing components to enable non-invasive glucose measurements. The instrument was calibrated using sugar solution samples with known glucose concentrations. It was then tested using serum samples from diabetic patients with accuracy, which was evaluated using Clarke's grid analysis. Results: Testing of the designed glucometer revealed that 83% of the serum samples fell within zone A of Clarke's grid analysis, indicating high accuracy. The remaining 17% of samples were classified in zone B, with no samples falling in zones C, D, or E. Conclusion: The developed glucometer demonstrated higher accuracy in measuring glucose concentrations above 200 mg/dl. Despite the use of serum samples in this experiment, 83% of the results were located in zone A leads to the capability of non-invasively measuring blood glucose levels. Further studies are required to validate the device's accuracy in a larger population and assess its utility in clinical practice.