Evidence map›Paper›PMID 40918446›Full record

ArticleFrontiers in bioengineering and biotechnology2025

Application of artificial muscle e-rubber for healthcare sensing: verification of measurement properties as a smart insole.

Hidemasa Yoneda, Takashi Yamaga, Takeshi Fujiwara, Yoko Komori, Masatoshi Shimada, Yuki Kato, Shintaro Oyama, Shingo Shimoda, Michiro Yamamoto, Hitoshi Hirata

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Hidemasa YonedaHuman Enhancement and Hand Surgery, Nagoya University, Nagoya, Japan.
Takashi YamagaOrthopedic Surgery, Tsushima City Hospital, Tsushima, Japan.
Takeshi FujiwaraNew Value Business, Toyoda Gosei Co., Ltd., Ama, Japan.
Yoko KomoriNew Value Business, Toyoda Gosei Co., Ltd., Ama, Japan.
Masatoshi ShimadaNew Value Business, Toyoda Gosei Co., Ltd., Ama, Japan.
Yuki KatoOrthopedic Surgery, Chunichi Hospital, Nagoya, Japan.
Shintaro OyamaGraduate School of Medicine, Nagoya University, Nagoya, Japan.
Shingo ShimodaGraduate School of Medicine, Nagoya University, Nagoya, Japan.
Michiro YamamotoHuman Enhancement and Hand Surgery, Nagoya University, Nagoya, Japan.
Hitoshi HirataGraduate School of Medicine, Nagoya University, Nagoya, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electroactive polymer (EAP) artificial muscles are gaining attention in robotic control technologies. Among them, the development of self-sensing actuators that integrate sensing mechanisms within artificial muscles is highly anticipated. This study aimed to evaluate the accuracy and precision of the sensing capabilities of the e-Rubber (eR), an artificial muscle developed by Toyoda Gosei Co., Ltd., and to investigate its potential for healthcare sensing applications such as smart insoles. The objective was to transform the eR into a thin capacitor and estimate the applied load by sensing minute changes in the capacitance. The changes in the EAP dielectric constant, electrode area, and inter-electrode distance, all of which define the capacitance, are non-linear functions. The relationship with the external force also exhibits nonlinearity. To address this issue, we experimentally plotted the load and capacitance changes and derived a regression equation. We evaluated the sensing characteristics of both a stand-alone sensor and a sensor embedded in a smart insole, followed by a precision verification of the load estimation using the derived regression equation. Load-capacitance changes were measured up to 400 N at three conditions: 23 °C and 50% humidity, 40 °C and 50% humidity, and 40 °C and 80% humidity. For the standalone sensor, the coefficient of variation was less than 1.25% and the confidence interval was 0.25%, indicating high precision. However, for the sensor embedded within the insole housing, the coefficient of variation increased to less than 8%, and the confidence interval was 1.5%, likely owing to the influence of gaps within the insole structure. Regarding the load estimation equation, a 5th-order polynomial approximation (R

Indexed as

artificial musclecapacitance sensordielectric elastomere-rubbersensing for healthcaresmart insole

Identifiers

PMID40918446
PMCPMC12408638

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.