Evidence map›Paper›PMID 40920203›Full record

ArticleNeuroradiology2025

Comparative evaluation of the CGuard dual-layer stent and Carotid Wallstent for elective carotid artery stenting: a retrospective multicenter study.

Yves Leonard Voss, Mousa Zidan, Alexander Radbruch, Igor Fischer, Franziska Dorn, Hannes Nordmeyer

Abstract readMulticenter StudyComparative Study
In one paragraph

Article in Neuroradiology, 2025. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yves Leonard Voss *Department of Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn, Germany. yvesleonardvoss@gmail.com.
Mousa Zidan *Department of Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn, Germany.
Alexander RadbruchDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn, Germany.
Igor FischerNeurovascular Research Unit, Heinrich Heine University Düsseldorf, Düsseldorf, Germany.
Franziska DornDepartment of Diagnostic and Interventional Neuroradiology, University Hospital Bonn, Bonn, Germany.
Hannes NordmeyerDepartment of Diagnostic and Interventional Neuroradiology, Klinikum Solingen, Solingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study aims to evaluate the safety and efficacy of the CGuard dual-layer stent with its mesh embolic protection system (EPS) in elective cases for treatment of internal carotid artery stenosis and compares it to the Carotid Wallstent as benchmark.

methodsIn this retrospective, multicenter study, we analyzed data from consecutive patients who underwent carotid artery stenting with CGuard at two high-volume neurointerventional centers and compared them with prior consecutive patients treated with Carotid Wallstent (CWS), with and without a balloon guiding catheter (BGC) as protection, at the same institutions. Patient demographics, procedural details, clinical complications, early in-stent thrombosis and occlusion rates, and late follow-up restenosis rates were assessed.

resultsA total of 428 patients were treated, 144 with the CGuard stent, 203 with CWS + BGC and 83 with CWS-BGC, the majority of patients for symptomatic stenoses. Technical success was achieved in 98.6% of CGuard patients. No clinical complications were observed in CGuard patients, however the clinical complication rate was 2.96% (6/203) for CWS + BGC and 4.94% (4/83) for CWS-BGC patients (p = 0.052). The in-hospital stent occlusion rate was 0.69% (1/144) for CGuard and 2.1% (6/286) in CWS ± BGC patients (p = 0.49). On long-term follow-up (mean 9.9 months) the CGuard demonstrated a comparatively low rate of restenosis (6.25%) and retreatment (2.1%).

conclusionThe CGuard dual-layer stent was safe and effective for carotid artery stenting in our series. Its design appears to contribute to a low risk of periprocedural complications, high technical success rate, while maintaining restenosis rates comparable to the Carotid Wallstent.

Indexed as

Carotid StenosisEmbolic Protection DevicesStentsAgedAged, 80 and overFemaleHumansMaleMiddle AgedProsthesis DesignRetrospective StudiesTreatment OutcomeCarotid artery revascularizationCarotid artery stentingDual-layer mesh stent

Identifiers

PMID40920203
PMCPMC12743056

What Socratic holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the Socratic graph.